Your browser doesn't support javascript.
loading
Desferrithiocin analogue iron chelators: iron clearing efficiency, tissue distribution, and renal toxicity.
Bergeron, Raymond J; Wiegand, Jan; Bharti, Neelam; McManis, James S; Singh, Shailendra.
Afiliación
  • Bergeron RJ; Department of Medicinal Chemistry, University of Florida, JHMHC, Box 100485, Gainesville, FL 32610-0485, USA. rayb@ufl.edu
Biometals ; 24(2): 239-58, 2011 Apr.
Article en En | MEDLINE | ID: mdl-21103911
ABSTRACT
The current solution to iron-mediated damage in transfusional iron overload disorders is decorporation of excess unmanaged metal, chelation therapy. The clinical development of the tridentate chelator deferitrin (1, Table 1) was halted due to nephrotoxicity. It was then shown by replacing the 4'-(HO) of 1 with a 3,6,9-trioxadecyloxy group, the nephrotoxicity could be ameliorated. Further structure-activity relationship studies have established that the length and the position of the polyether backbone controlled (1) the ligand's iron clearing efficiency (ICE), (2) chelator tissue distribution, (3) biliary ferrokinetics, and (4) tissue iron reduction. The current investigation compares the ICE and tissue distribution of a series of (S)-4,5-dihydro-2-[2-hydroxy-4-(polyether)phenyl]-4-methyl-4-thiazolecarboxylic acids (Table 1, 3-5) and the (S)-4,5-dihydro-2-[2-hydroxy-3-(polyether)phenyl]-4-methyl-4-thiazolecarboxylic acids (Table 1, 8-10). The three most effective polyether analogues, in terms of performance ratio (PR), defined as mean ICE(primate)/ICE(rodent), are 3 (PR 1.1), 8, (PR 1.5), and 9, now in human trials, (PR 2.2). At the onset of the clinical trial on 9, no data were available for ligand 3 or 8. This is unfortunate, as 3 has many advantages over 9, e.g., the ICE of 3 in rats is 2.5-fold greater than that of 9 and analogue 3 achieves very high levels in the liver, pancreas, and heart, the organs most affected by iron overload. Finally, the impact of 3 on the urinary excretion of kidney injury molecule-1 (Kim-1), an early diagnostic biomarker for monitoring acute kidney toxicity, has been carried out in rats; no evidence of nephrotoxicity was found. Overall, the results suggest that 3 would be a far superior clinical candidate to 9.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tiazoles / Dihidropiridinas / Quelantes del Hierro / Hierro / Riñón Límite: Animals Idioma: En Revista: Biometals Asunto de la revista: BIOQUIMICA Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tiazoles / Dihidropiridinas / Quelantes del Hierro / Hierro / Riñón Límite: Animals Idioma: En Revista: Biometals Asunto de la revista: BIOQUIMICA Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos