Your browser doesn't support javascript.
loading
The Cohn felt plug: an effective HeartMate II® reimplantation technique.
Stone, Matthew L; Kilic, Ahmet; Kennedy, Jamie L W; Bergin, James D; Kern, John A.
Afiliación
  • Stone ML; Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Virginia Health System, Charlottesville, Virginia 22908-0679, USA.
J Card Surg ; 27(1): 122-4, 2012 Jan.
Article en En | MEDLINE | ID: mdl-22321118
ABSTRACT
We report the first documented case of HeartMate II® left ventricular assist device (LVAD) reimplantation following Cohn Teflon felt plug repair of the initial left ventricular apical cannulation site. This case highlights the current limitations of the predictability of myocardial recovery while describing an effective technique for possible future LVAD reimplantation.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Trastornos Puerperales / Reimplantación / Cardiomiopatía Dilatada / Corazón Auxiliar Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans Idioma: En Revista: J Card Surg Asunto de la revista: CARDIOLOGIA Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Trastornos Puerperales / Reimplantación / Cardiomiopatía Dilatada / Corazón Auxiliar Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans Idioma: En Revista: J Card Surg Asunto de la revista: CARDIOLOGIA Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos