Your browser doesn't support javascript.
loading
Noninvasive ventilation and breathing-swallowing interplay in chronic obstructive pulmonary disease*.
Terzi, Nicolas; Normand, Hervé; Dumanowski, Edith; Ramakers, Michel; Seguin, Amélie; Daubin, Cédric; Valette, Xavier; Masson, Romain; Sauneuf, Bertrand; Charbonneau, Pierre; du Cheyron, Damien; Lofaso, Frédéric.
Afiliación
  • Terzi N; 1Inserm, U 1075 COMETE, Caen, 14032, France. 2UCBN, COMETE, Caen, 14032, France. 3Service de Réanimation Médicale, CHRU, Caen, France. 4Service d'Explorations Fonctionnelles Respiratoire, CHRU, Caen, France. 5Service de Réanimation, CH Saint-Lô Memorial France-Etat-Unis, Saint-Lô, France. 6UCBN, U2RM, Caen, 14032, France. 7Centre d'Investigation Clinique-Innovations Technologiques, Services de Physiologie-Explorations Fonctionnelles, Hôpital Raymond Poincaré, AP-HP, EA 4497, Université de Versai
Crit Care Med ; 42(3): 565-73, 2014 Mar.
Article en En | MEDLINE | ID: mdl-24145847
OBJECTIVES: To investigate breathing-swallowing interactions in patients with chronic obstructive pulmonary disease requiring noninvasive mechanical ventilation and, if needed, to develop a technical modification of the ventilator designed to eliminate ventilator insufflations during swallowing. DESIGN: We conducted a prospective, open-label, interventional study. PATIENTS: Fifteen consecutive chronic obstructive pulmonary disease patients with exacerbations requiring ICU admission and NIV. INTERVENTIONS: Swallowing performance and breathing-swallowing interactions were investigated noninvasively by chin electromyography, cervical piezoelectric sensor, and inductive respiratory plethysmography. Two water-bolus sizes (5 and 10 mL) were tested in random order. Swallowing was tested with and without noninvasive mechanical ventilation, in random order. First, a standard mechanical ventilator capable of delivering noninvasive mechanical ventilation was used. Second, a marketed device was equipped with an off-switch for use during swallowing. MEASUREMENTS AND MAIN RESULTS: Swallowing performance and breathing-swallowing interactions were investigated noninvasively by chin electromyography, cervical piezoelectric sensor, and inductive respiratory plethysmography. Two water bolus sizes (5 and 10 mL) were tested in random order. Swallowing was tested with and without noninvasive mechanical ventilation in random order. First, a standard mechanical ventilator capable of delivering noninvasive mechanical ventilation was used. Swallowing efficiency, breathing-swallowing synchronization, and Borg Scale dyspnea scores improved significantly with noninvasive mechanical ventilation. However, swallowing induced ventilator triggering followed by autotriggering. To improve patient-ventilator synchrony, a marketed device was equipped with an off-switch for use during swallowing. This device completely eliminated swallowing-induced ventilator triggering and postswallow autotriggering. CONCLUSION: Patients with chronic obstructive pulmonary disease admitted to the ICU for acute exacerbations had abnormal breathing-swallowing interactions and dyspnea, which improved with noninvasive mechanical ventilation. Furthermore, a ventilator device with a simple switch-off pushbutton to eliminate insufflations during swallows prevented swallowing-induced ventilator triggering and postswallow autotriggering.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Respiración / Enfermedad Pulmonar Obstructiva Crónica / Deglución / Ventilación no Invasiva / Unidades de Cuidados Intensivos Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Med Año: 2014 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Respiración / Enfermedad Pulmonar Obstructiva Crónica / Deglución / Ventilación no Invasiva / Unidades de Cuidados Intensivos Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Med Año: 2014 Tipo del documento: Article