Your browser doesn't support javascript.
loading
Effect of saliva contamination on the shear bond strength of a new self-etch adhesive system to dentin.
Munaga, Swapna; Chitumalla, Rajkiran; Kubigiri, Satheesh Kr; Rawtiya, Manjusha; Khan, Sheeba; Sajjan, Parappa.
Afiliación
  • Munaga S; Department of Conservative Dentistry and Endodontics, People's College of Dental Sciences, Bhopal, India.
  • Chitumalla R; Department of Prosthodontics, People's College of Dental Sciences, Bhopal, India.
  • Kubigiri SK; Department of Preventive and Community Dentistry, Mamatha Dental College, Khammam, Andhra Pradesh, India.
  • Rawtiya M; Department of Conservative Dentistry and Endodontics, People's College of Dental Sciences, Bhopal, India.
  • Khan S; Department of Conservative Dentistry and Endodontics, People's College of Dental Sciences, Bhopal, India.
  • Sajjan P; Department of Preventive and Community Dentistry, PMNM Dental College and Hospital Bagalkot, Karnataka, India.
J Conserv Dent ; 17(1): 31-4, 2014 Jan.
Article en En | MEDLINE | ID: mdl-24554857
AIMS AND OBJECTIVES: To evaluate the effect of saliva contamination on the shear bond strength of a new two-step self-etch adhesive (P90 system adhesive) to dentin and to determine the effect of contaminant removing treatments on the recovery of bond strengths. MATERIALS AND METHODS: The buccal surfaces of 40 human premolars were ground to expose dentin. The specimens were randomly divided into four groups. Group 1 is uncontaminated and serves as the control group. Further groups were divided based on the step in the bonding sequence when the contamination had occurred as follows: Group 2 (primer, saliva contamination, rinse and dry), group 3 (after procedure of group 2, reapplication of primer), and group 4 (after procedure like in control group, saliva contamination, rinse and dry). Filtek P90 composite resin cylinders of 3 mm diameter and 3 mm length were fabricated on the surfaces. Shear bond strength testing was done in an Instron Universal Testing Machine and the data were subjected to one-way analysis of variance (ANOVA) and Student's t-test. RESULTS: With P90 system adhesive, group 2 and group 4 showed lower shear bond strength than group 1 (control) and group 3 (P < 0.05). CONCLUSION: Saliva contamination significantly decreased the shear bond strength of the adhesive to dentin.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Conserv Dent Año: 2014 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Conserv Dent Año: 2014 Tipo del documento: Article País de afiliación: India