Your browser doesn't support javascript.
loading
Absolute and relative quantification of RNA modifications via biosynthetic isotopomers.
Kellner, Stefanie; Ochel, Antonia; Thüring, Kathrin; Spenkuch, Felix; Neumann, Jennifer; Sharma, Sunny; Entian, Karl-Dieter; Schneider, Dirk; Helm, Mark.
Afiliación
  • Kellner S; Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, 55099 Mainz, Germany.
  • Ochel A; Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, 55099 Mainz, Germany.
  • Thüring K; Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, 55099 Mainz, Germany.
  • Spenkuch F; Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, 55099 Mainz, Germany.
  • Neumann J; Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, 55099 Mainz, Germany.
  • Sharma S; Institute for Molecular Biosciences, Johann-Wolfgang Goethe University, 60438 Frankfurt am Main, Germany.
  • Entian KD; Institute for Molecular Biosciences, Johann-Wolfgang Goethe University, 60438 Frankfurt am Main, Germany.
  • Schneider D; Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, 55099 Mainz, Germany.
  • Helm M; Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, 55099 Mainz, Germany mhelm@uni-mainz.de.
Nucleic Acids Res ; 42(18): e142, 2014 Oct.
Article en En | MEDLINE | ID: mdl-25129236
ABSTRACT
In the resurging field of RNA modifications, quantification is a bottleneck blocking many exciting avenues. With currently over 150 known nucleoside alterations, detection and quantification methods must encompass multiple modifications for a comprehensive profile. LC-MS/MS approaches offer a perspective for comprehensive parallel quantification of all the various modifications found in total RNA of a given organism. By feeding (13)C-glucose as sole carbon source, we have generated a stable isotope-labeled internal standard (SIL-IS) for bacterial RNA, which facilitates relative comparison of all modifications. While conventional SIL-IS approaches require the chemical synthesis of single modifications in weighable quantities, this SIL-IS consists of a nucleoside mixture covering all detectable RNA modifications of Escherichia coli, yet in small and initially unknown quantities. For absolute in addition to relative quantification, those quantities were determined by a combination of external calibration and sample spiking of the biosynthetic SIL-IS. For each nucleoside, we thus obtained a very robust relative response factor, which permits direct conversion of the MS signal to absolute amounts of substance. The application of the validated SIL-IS allowed highly precise quantification with standard deviations<2% during a 12-week period, and a linear dynamic range that was extended by two orders of magnitude.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: ARN / Cromatografía Liquida / Espectrometría de Masas en Tándem Idioma: En Revista: Nucleic Acids Res Año: 2014 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: ARN / Cromatografía Liquida / Espectrometría de Masas en Tándem Idioma: En Revista: Nucleic Acids Res Año: 2014 Tipo del documento: Article País de afiliación: Alemania