Your browser doesn't support javascript.
loading
An LC-MS/MS method for serum methylmalonic acid suitable for monitoring vitamin B12 status in population surveys.
Mineva, Ekaterina M; Zhang, Mindy; Rabinowitz, Daniel J; Phinney, Karen W; Pfeiffer, Christine M.
Afiliación
  • Mineva EM; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA, 30341, USA.
Anal Bioanal Chem ; 407(11): 2955-64, 2015 Apr.
Article en En | MEDLINE | ID: mdl-25258283
Methylmalonic acid (MMA), a functional indicator of vitamin B12 insufficiency, was measured in the US population in the National Health and Nutrition Examination Survey (NHANES) from 1999 to 2004 using a GC/MS procedure that required 275 µL of sample and had a low throughput (36 samples/run). Our objective was to introduce a more efficient yet highly accurate LC-MS/MS method for NHANES 2011-2014. We adapted the sample preparation with some modifications from a published isotope-dilution LC-MS/MS procedure. The procedure utilized liquid-liquid extraction and generation of MMA dibutyl ester. Reversed-phase chromatography with isocratic elution allowed baseline resolution of MMA from its naturally occurring structural isomer succinic acid within 4.5 min. Our new method afforded an increased throughput (≤160 samples/run) and measured serum MMA with high sensitivity (LOD = 22.1 nmol/L) in only 75 µL of sample. Mean (±SD) recovery of MMA spiked into serum (2 d, 4 levels, 2 replicates each) was 94 % ± 5.5 %. Total imprecision (41 d, 2 replicates each) for three serum quality control pools was 4.9 %-7.9 % (97.1-548 nmol/L). The LC-MS/MS method showed excellent correlation (n = 326, r = 0.99) and no bias (Deming regression, Bland-Altman analysis) compared to the previous GC/MS method. Both methods produced virtually identical mean (±SD) MMA concentrations [LC-MS/MS: 18.47 ± 0.71 ng/mL (n = 17), GC/MS: 18.18 ± 0.67 ng/mL (n = 11)] on a future plasma reference material compared with a GC/MS method procedure from the National Institute of Standards and Technology [18.41 ± 0.70 ng/mL (n = 15)]. No adjustment will be necessary to compare previous (1999-2004) to future (2011-2014) NHANES MMA data.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Vitamina B 12 / Cromatografía Liquida / Espectrometría de Masas en Tándem / Ácido Metilmalónico Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2015 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Vitamina B 12 / Cromatografía Liquida / Espectrometría de Masas en Tándem / Ácido Metilmalónico Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2015 Tipo del documento: Article País de afiliación: Estados Unidos