Your browser doesn't support javascript.
loading
Zirconia abutments for single-tooth implant restorations: a 10- to 11-year follow-up study.
Ekfeldt, Anders; Fürst, Björn; Carlsson, Gunnar E.
Afiliación
  • Ekfeldt A; Department of Prosthetic Dentistry and Oral Function, Faculty of Dentistry, Institute of Clinical Dentistry, University of Oslo, Oslo, Norway.
  • Fürst B; Specialist Clinic of Prosthetic Dentistry, Public Dental Health Service, Västra Götaland, Mölndal Hospital, Mölndal, Sweden.
  • Carlsson GE; Department of Prosthetic Dentistry/Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Clin Oral Implants Res ; 28(10): 1303-1308, 2017 Oct.
Article en En | MEDLINE | ID: mdl-27663724
ABSTRACT

OBJECTIVES:

To evaluate the clinical outcome of custom-made zirconia abutments for implant-supported single-tooth restorations 10-11 years after insertion. MATERIAL AND

METHODS:

The study comprises a clinical examination of 23 patients with 30 restorations placed 10-11 years ago. Oral surgeons placed the implants. The prosthodontic treatment was provided at a prosthodontic specialist clinic. The restoration was either an all-ceramic crown for cementation or a screw-retained one-piece restoration with the veneering porcelain baked directly to the zirconia abutment. Besides the clinical and radiographic examination at the 10- to 11-year follow-up, the patients' records were scrutinized regarding clinical and radiographic data from insertion of the restoration up to the last visit at the clinic.

RESULTS:

The zirconia abutments performed well. Both technical and biological complications were rare; most patients were in general extremely satisfied with the restorations. No all-ceramic crowns fractured during the observation period. One implant was lost after 5½ years in service. There were no significant differences for changes in any of the soft tissue registrations or the peri-implant marginal bone level between the conventional two-piece abutment-crown restoration and the one-piece restoration. The peri-implant bone level changes from placement to the clinical examination 10-11 years later were small (mean 0.26 mm, SD 0.6 mm).

CONCLUSIONS:

Zirconia abutments for single-implant crowns demonstrated excellent technical and biological results over 10-11 years of function, and most patients were extremely satisfied with the aesthetics and the function of their single-implant restorations.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Circonio / Pilares Dentales / Prótesis Dental de Soporte Implantado / Implantes Dentales de Diente Único / Materiales Dentales Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adult / Humans / Middle aged Idioma: En Revista: Clin Oral Implants Res Asunto de la revista: ODONTOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Noruega

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Circonio / Pilares Dentales / Prótesis Dental de Soporte Implantado / Implantes Dentales de Diente Único / Materiales Dentales Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adult / Humans / Middle aged Idioma: En Revista: Clin Oral Implants Res Asunto de la revista: ODONTOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Noruega