Your browser doesn't support javascript.
loading
Comparison of fast electron transfer kinetics at platinum, gold, glassy carbon and diamond electrodes using Fourier-transformed AC voltammetry and scanning electrochemical microscopy.
Tan, Sze-Yin; Lazenby, Robert A; Bano, Kiran; Zhang, Jie; Bond, Alan M; Macpherson, Julie V; Unwin, Patrick R.
Afiliación
  • Tan SY; Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, UK. p.r.unwin@warwick.ac.uk and School of Chemistry, Monash University, Clayton, Victoria 3800, Australia. jie.zhang@monash.edu alan.bond@monash.edu.
  • Lazenby RA; Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, UK. p.r.unwin@warwick.ac.uk.
  • Bano K; School of Chemistry, Monash University, Clayton, Victoria 3800, Australia. jie.zhang@monash.edu alan.bond@monash.edu.
  • Zhang J; School of Chemistry, Monash University, Clayton, Victoria 3800, Australia. jie.zhang@monash.edu alan.bond@monash.edu.
  • Bond AM; School of Chemistry, Monash University, Clayton, Victoria 3800, Australia. jie.zhang@monash.edu alan.bond@monash.edu.
  • Macpherson JV; Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, UK. p.r.unwin@warwick.ac.uk.
  • Unwin PR; Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, UK. p.r.unwin@warwick.ac.uk.
Phys Chem Chem Phys ; 19(13): 8726-8734, 2017 Mar 29.
Article en En | MEDLINE | ID: mdl-28317963
ABSTRACT
Heterogeneous electron transfer (ET) processes at electrode/electrolyte interfaces are of fundamental and applied importance and are extensively studied by a range of electrochemical techniques, all of which have various attributes but also limitations. The present study focuses on the one-electron oxidation of tetrathiafulvalene (TTF) and reduction of tetracyanoquinodimethane (TCNQ) in acetonitrile solution by two powerful electrochemical techniques Fourier-transformed large amplitude alternating current voltammetry (FTACV); and scanning electrochemical microscopy (SECM), both of which are supported by detailed theoretical models. At conventional Pt, Au and glassy carbon (GC) electrode materials, the apparent (overall) charge transfer kinetic values determined by FTACV give standard ET rate constants, k, that are fast and close to the reversible limit. They are in good agreement with highly localised k measurements determined by SECM under conditions of high mass transport rates. In contrast, the impact of both the complex heterogeneous surface of polycrystalline boron doped diamond (pBDD) and degenerate p-type doping results in a range of k values across the electrode surface compared to the overall k measured for both processes studied. Moreover, the reduced availability of charge carriers at the electrode surface, at each energy state, compared to a metal, which decreases as the potential becomes more negative, results in lower k0 values at pBDD than Pt, Au and GC. The measurement technique also has an influence SECM measurements are made at much higher local current density than FTACV, and for TCNQ/TCNQ˙-, which has the more negative formal potential, limited charge carrier availability results in k > k, with unusual apparent charge transfer coefficients and voltammetric waveshapes from SECM. These data thus highlight the importance of understanding the influence of the measurement technique and further demonstrate how ET kinetics at pBDD differ from conventional electrodes, in this case for processes in an organic solvent, which has received much less attention compared to aqueous systems for studies with pBDD.

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Phys Chem Chem Phys Asunto de la revista: BIOFISICA / QUIMICA Año: 2017 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Phys Chem Chem Phys Asunto de la revista: BIOFISICA / QUIMICA Año: 2017 Tipo del documento: Article