Your browser doesn't support javascript.
loading
Chimney Technique with the INCRAFT® AAA Stent Graft System to Treat Pararenal Aortic Aneurysm in Narrowed Iliac Axes.
Montelione, Nunzio; Sirignano, Pasqualino; Mansour, Wassim; Formiconi, Martina; Capoccia, Laura; Speziale, Francesco.
Afiliación
  • Montelione N; Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Sapienza University of Rome, Rome, Italy. Electronic address: nunzio_montelione@hotmail.it.
  • Sirignano P; Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Sapienza University of Rome, Rome, Italy.
  • Mansour W; Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Sapienza University of Rome, Rome, Italy.
  • Formiconi M; Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Sapienza University of Rome, Rome, Italy.
  • Capoccia L; Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Sapienza University of Rome, Rome, Italy.
  • Speziale F; Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Sapienza University of Rome, Rome, Italy.
Ann Vasc Surg ; 44: 421.e9-421.e13, 2017 Oct.
Article en En | MEDLINE | ID: mdl-28483632
ABSTRACT
To report a case of pararenal aortic aneurysm (PAAA) with narrowed iliac arteries treated by the chimney technique combined with the INCRAFT® AAA stent graft system. A 75-year-old man was diagnosed with a 55-mm PAAA. Patient was judged unfit for open repair and for standard endovascular aneurysm repair (EVAR) due to its clinical and anatomical requirements. Custom-made fenestrated device (FEVAR) was excluded due to the presence of narrowed and heavily calcified iliac axes. Consequently, patient underwent auspicious endovascular aneurysm repair with the INCRAFT System and chimney grafts in the superior mesenteric artery and both renal arteries. At 12 months' follow-up, patient was in good clinical condition, with preserved renal function. Computed tomographic angiography revealed inceptive shrinkage of the aneurysm with patency of aortic and visceral grafts even in the presence of a low-flow type Ia endoleak. Chimney grafts (CGs) combined with the low-profile INCRAFT System seem to be feasible for treating PAAA, in high-risk patients unfit for standard EVAR or FEVAR devices.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Prótesis Vascular / Stents / Aneurisma de la Aorta Abdominal / Implantación de Prótesis Vascular / Procedimientos Endovasculares / Arteria Ilíaca Límite: Aged / Humans / Male Idioma: En Revista: Ann Vasc Surg Asunto de la revista: ANGIOLOGIA Año: 2017 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Prótesis Vascular / Stents / Aneurisma de la Aorta Abdominal / Implantación de Prótesis Vascular / Procedimientos Endovasculares / Arteria Ilíaca Límite: Aged / Humans / Male Idioma: En Revista: Ann Vasc Surg Asunto de la revista: ANGIOLOGIA Año: 2017 Tipo del documento: Article