Outcome Improvement for Hypothermic Machine Perfusion Versus Cold Storage for Kidneys From Cardiac Death Donors.
Zhong, Zibiao; Lan, Jia'nan; Ye, Shaojun; Liu, Zhongzhong; Fan, Lin; Zhang, Yang; Fu, Zhen; Qiao, Bingbing; Shiu-Chung Ko, Dicken; Wang, Yanfeng; Ye, Qifa.
Afiliación
  • Zhong Z; Wuhan University, Zhongnan Hospital of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Transplant Center of Wuhan University, Hubei Key Laboratory of Medical Technology on Transplantation, Wuhan, Hubei.
  • Lan J; Wuhan University, Zhongnan Hospital of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Transplant Center of Wuhan University, Hubei Key Laboratory of Medical Technology on Transplantation, Wuhan, Hubei.
  • Ye S; Wuhan University, Zhongnan Hospital of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Transplant Center of Wuhan University, Hubei Key Laboratory of Medical Technology on Transplantation, Wuhan, Hubei.
  • Liu Z; Wuhan University, Zhongnan Hospital of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Transplant Center of Wuhan University, Hubei Key Laboratory of Medical Technology on Transplantation, Wuhan, Hubei.
  • Fan L; Wuhan University, Zhongnan Hospital of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Transplant Center of Wuhan University, Hubei Key Laboratory of Medical Technology on Transplantation, Wuhan, Hubei.
  • Zhang Y; Wuhan University, Zhongnan Hospital of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Transplant Center of Wuhan University, Hubei Key Laboratory of Medical Technology on Transplantation, Wuhan, Hubei.
  • Fu Z; Research Center of National Health Ministry on Transplantation Medicine Engineering and Technology, The 3rd Xiangya Hospital of Central South University, Changsha, China.
  • Qiao B; Wuhan University, Zhongnan Hospital of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Transplant Center of Wuhan University, Hubei Key Laboratory of Medical Technology on Transplantation, Wuhan, Hubei.
  • Shiu-Chung Ko D; Research Center of National Health Ministry on Transplantation Medicine Engineering and Technology, The 3rd Xiangya Hospital of Central South University, Changsha, China.
  • Wang Y; Wuhan University, Zhongnan Hospital of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Transplant Center of Wuhan University, Hubei Key Laboratory of Medical Technology on Transplantation, Wuhan, Hubei.
  • Ye Q; Department of Urology, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA.
Artif Organs ; 41(7): 647-653, 2017 Jul.
Article en En | MEDLINE | ID: mdl-28703374
ABSTRACT
Organ shortage has led to an increased use of kidneys from cardiac death donors (DCDs), but controversies about the methods of organ preservation still exist. This study aims to compare the effect of machine perfusion (MP) and cold storage (CS) in protecting kidneys harvested from DCDs. 141 kidney pairs from DCDs between July 2010 and July 2015 were included in this randomized controlled study. One kidney from each donor was randomly assigned to MP and the contralateral kidney was assigned to CS. Delayed graft function (DGF) rate, resistance index of renal arteries, early renal function, and survival rates were used to estimate the effect of preservation. The results showed that MP decreased the rate of DGF from 33.3 to 22.0% (P = 0.033). Ultrasound of the kidneys within 48 h after transplantation showed that the resistance index of renal main artery (0.673 ± 0.063 vs. 0.793 ± 0.124, P < 0.001), sub segmental artery (0.66 ± 0.062 vs. 0.764 ± 0.077, P < 0.001) and interlobular artery (0.648 ± 0.056 vs. 0.745 ± 0.111, P = 0.023) were all significantly lower in the MP group than those in the CS group. Furthermore, compared to the CS group, in the first 7 days following transplantation, the median urine volume was significantly higher (4080 mL vs. 3000 mL, P = 0.047) in kidneys sustained using MP and the median serum creatinine was remarkably lower (180 µmol/L vs. 390 µmol/L, P = 0.024). More importantly, MP group had higher 1- and 3-year graft survival rates (98% vs. 93%, P = 0.026; 93% vs. 82%, P = 0.036, respectively). Hypothermic MP improved the outcomes of DCD kidney transplantation.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Preservación de Órganos / Perfusión / Trasplante de Riñón / Riñón Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Organs Año: 2017 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Preservación de Órganos / Perfusión / Trasplante de Riñón / Riñón Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Organs Año: 2017 Tipo del documento: Article