Your browser doesn't support javascript.
loading
Plasma Treatment of Polymer Powder as an Effective Tool to Functionalize Polymers: Case Study Application on an Amphiphilic Polyurethane.
Laurano, Rossella; Boffito, Monica; Torchio, Alessandro; Cassino, Claudio; Chiono, Valeria; Ciardelli, Gianluca.
Afiliación
  • Laurano R; Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
  • Boffito M; Department of Surgical Sciences, Università degli Studi di Torino, Corso Dogliotti 14, 10126 Torino, Italy.
  • Torchio A; Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
  • Cassino C; Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
  • Chiono V; Department of Surgical Sciences, Università degli Studi di Torino, Corso Dogliotti 14, 10126 Torino, Italy.
  • Ciardelli G; Department of Science and Technological Innovation, Università del Piemonte Orientale, Viale Teresa Michel 11, 15121 Alessandria, Italy.
Polymers (Basel) ; 11(12)2019 Dec 16.
Article en En | MEDLINE | ID: mdl-31888117
ABSTRACT
Plasma treatment is a widely applied, easy, fast, and highly reproducible surface modification technique. In this work powder plasma treatment was exploited to expose carboxylic groups along the backbone of a water soluble polymer. Specifically, a custom-made amphiphilic poly(ether urethane) containing Poloxamer® 407 blocks (Mw = 54,000 Da) was first synthesized and its powders were plasma treated in the presence of Acrylic Acid vapor. To maximize -COOH group exposure while preventing polymer degradation, different Ar gas flow rates (i.e., 10, 30, and 50 sccm) were investigated. Upon gas flow increase, significant polymer degradation was observed, with a 35% molecular weight reduction at 50 sccm Ar flow rate. On the other hand, the highest number of exposed carboxylic groups (5.3 × 1018 ± 5.5 × 1017 units/gpolymer) was obtained by setting gas flow at 10 sccm. Hence, a gas flow of 10 sccm turned out to be the best set-up to maximize -COOH exposure while preventing degradation phenomena. Additionally, upon plasma treatment, no detrimental effects were observed in the thermoresponsiveness of polymer aqueous solutions, which was ensured by Poloxamer® 407 blocks. Therefore, the newly developed technology here applied on an amphiphilic poly(ether urethane) could pave the way to the tailored design of a plethora of different multifunctional hydrogels.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Polymers (Basel) Año: 2019 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Polymers (Basel) Año: 2019 Tipo del documento: Article País de afiliación: Italia