Surgical technique for placement of the automated low flow ascites pump (Alfapump).
Dembinski, J; Aranovich, D; Banz, V; Ehmann, T; Klein, I; Malago, M; Richter, N; Schnitzbauer, A A; Staszewicz, W; Tautenhahn, H-M; Capel, J; Regimbeau, J-M.
Afiliación
  • Dembinski J; Department of Digestive Surgery, Amiens, University of Picardie, Avenue René Laennec, 80054, Amiens Cedex, France.
  • Aranovich D; Department of General Surgery, Rabin Medical Center, Beilinson Hospital, Petah Tikva, Israel.
  • Banz V; Department of Visceral and Surgery and Medicine, University Hospital Bern, Inselspital, and University of Bern, Bern, Switzerland.
  • Ehmann T; General and Visceral Surgery, St Josef Hospital Haan, Haan, Germany.
  • Klein I; Transplantation and hepatobilliary surgery, Universitätsklinikum Würzburg, Würzburg, Germany.
  • Malago M; Hepato-pancreatic-biliary and Liver Transplantation Surgery, Royal Free Hospital, University College London, London, United Kingdom.
  • Richter N; General and Visceral Surgery, Medizinische Hochschule Hannover, Hannover, Germany.
  • Schnitzbauer AA; Department of General and Visceral Surgery, University Hospital Frankfurt, Goethe-University Frankfurt/Main, Frankfurt, Germany.
  • Staszewicz W; Department of Surgery, Service of Visceral Surgery, Geneva University Hospitals, Geneva, Switzerland.
  • Tautenhahn HM; General and Visceral Surgery, Universitätsklinikum Jena, Jena, Germany.
  • Capel J; Sequana Medical AG, Technoparkstrasse 1, 8005, Zürich, Switzerland.
  • Regimbeau JM; Department of Digestive Surgery, Amiens, University of Picardie, Avenue René Laennec, 80054, Amiens Cedex, France. regimbeau.jean-marc@chu-amiens.fr.
Langenbecks Arch Surg ; 405(1): 117-123, 2020 Feb.
Article en En | MEDLINE | ID: mdl-31915920
Approximately 10% of patients with ascites associated with cirrhosis fail to respond to dietary rules and diuretic treatment and therefore present with refractory ascites. In order to avoid iterative large-volume paracentesis in patients with contraindication to TIPS, the automated low flow ascites pump system (Alfapump) was developed to pump ascites from the peritoneal cavity into the urinary bladder, where it is eliminated spontaneously by normal micturition. This manuscript reports the surgical technique for placement of the Alfapump.