Your browser doesn't support javascript.
loading
Are hemodynamics of irregular small carotid-ophthalmic aneurysms different from those of regular ones and large aneurysms based on numerical simulation?
Wan, Hailin; Huang, Lei; Ge, Liang; Jiang, Yeqing; Li, Gaohui; Leng, Xiaochang; Feng, Xiaoyuan; Xiang, Jianping; Zhang, Xiaolong.
Afiliación
  • Wan H; Department of Radiology, Huashan Hospital, Fudan University, No. 12 Middle Wulumuqi Road, Shanghai, 200040, China.
  • Huang L; Department of Radiology, Huashan Hospital, Fudan University, No. 12 Middle Wulumuqi Road, Shanghai, 200040, China.
  • Ge L; Department of Radiology, Huashan Hospital, Fudan University, No. 12 Middle Wulumuqi Road, Shanghai, 200040, China.
  • Jiang Y; Department of Radiology, Huashan Hospital, Fudan University, No. 12 Middle Wulumuqi Road, Shanghai, 200040, China.
  • Li G; ArteryFlow Technology Co., Ltd, 459 Qianmo Road, Hangzhou, 310051, China.
  • Leng X; ArteryFlow Technology Co., Ltd, 459 Qianmo Road, Hangzhou, 310051, China.
  • Feng X; Department of Radiology, Huashan Hospital, Fudan University, No. 12 Middle Wulumuqi Road, Shanghai, 200040, China.
  • Xiang J; ArteryFlow Technology Co., Ltd, 459 Qianmo Road, Hangzhou, 310051, China.
  • Zhang X; Department of Radiology, Huashan Hospital, Fudan University, No. 12 Middle Wulumuqi Road, Shanghai, 200040, China. xiaolongzhang@fudan.edu.cn.
Neuroradiology ; 62(4): 511-518, 2020 Apr.
Article en En | MEDLINE | ID: mdl-31925470
ABSTRACT

PURPOSE:

The purpose of this study is to investigate whether hemodynamics of unruptured, irregular small intracranial aneurysms (SIAs) are different from those of regular ones and large intracranial aneurysms (LIAs) in ophthalmic artery segment of internal carotid artery (ICA).

METHODS:

Between April 2015 and June 2018, 106 carotid-ophthalmic artery aneurysms were retrospectively analyzed using 3D angiographic images and computational fluid dynamics (CFD). Three categories were stratified regular SIAs, irregular SIAs and LIAs. Statistical comparisons of the differences in clinical, morphological and hemodynamic parameters among regular SIA, irregular SIA and LIA groups were performed by one-way analysis of variance (ANOVA) or Kruskal-Wallis Test.

RESULTS:

The median maximal height of regular SIA, irregular SIA and LIA were 3.03 (interquartile range 2.49-4.22) mm, 4.59 (interquartile range 3.86-5.32) mm and 11.06 (interquartile range 9.28-13.69) mm, all P < 0.05). Low shear-stress area percentage (LSA%) and oscillatory shear index (OSI) of irregular SIAs and LIAs were not significantly different (P = 0.72, P = 0.27 respectively), and were significantly higher than those of regular SIAs (all P < 0.01). Wall shear stress (WSS) and normalized wall shear stress (NWSS) of irregular SIAs were significantly higher than those of LIAs (P < 0.01, P < 0.01 respectively), but lower than those of regular SIAs (P < 0.01, P < 0.01 respectively).

CONCLUSIONS:

Special unruptured irregular SIAs share a similarity of hemodynamic characteristics with LIAs in high LSA% and high OSI, and are different from regular SIAs in hemodynamics.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Arteria Oftálmica / Angiografía Cerebral / Arterias Carótidas / Aneurisma Intracraneal Tipo de estudio: Observational_studies / Prognostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Neuroradiology Año: 2020 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Arteria Oftálmica / Angiografía Cerebral / Arterias Carótidas / Aneurisma Intracraneal Tipo de estudio: Observational_studies / Prognostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Neuroradiology Año: 2020 Tipo del documento: Article País de afiliación: China