Your browser doesn't support javascript.
loading
Novel insights on outcome in horizontal aorta with self-expandable new-generation transcatheter aortic valve replacement devices.
Veulemans, Verena; Maier, Oliver; Bosbach, Georg; Polzin, Amin; Piayda, Kerstin; Afzal, Shazia; Jung, Christian; Westenfeld, Ralf; Kelm, Malte; Zeus, Tobias.
Afiliación
  • Veulemans V; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Maier O; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Bosbach G; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Polzin A; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Piayda K; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Afzal S; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Jung C; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Westenfeld R; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Kelm M; Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
  • Zeus T; CARID (Cardiovascular Research Institute Düsseldorf), Heinrich Heine University, Medical Faculty, Düsseldorf, Germany.
Catheter Cardiovasc Interv ; 96(7): 1511-1519, 2020 12.
Article en En | MEDLINE | ID: mdl-32374924
BACKGROUND: The impact of a horizontal aorta (HA) on adverse events (AE) following in transcatheter aortic valve replacement (TAVR) is dealt controversially. Using new-generation self-expandable devices, we aimed to reevaluate an appropriate threshold of the aortic root angulation (ARA) in terms of HA and its impact on outcome. METHODS: The 466 consecutive patients, who underwent transfemoral TAVR with self-expandable new-generation devices, were analyzed. Patients were classified into cases with HA (ARA ≥ 51°; n = 225; 48%) and without HA (ARA <51°; n = 241; 52%). Primary endpoints were device success and 30-day mortality. Secondary endpoints were specific AE according to VARC-2 definitions. RESULTS: Contrast use (107.6 ± 50.1 vs. 94.1 ± 46.1 ml; p = .033) and radiation dose (3,176 [1,928-5,596] vs. 2,651 [1,643-4,394] Gyxcm2 ; p = .016) were higher in HA. Primary device success was comparable (97.1 vs. 97.8%; p = .773). A 30-day mortality (3.3 vs. 0.4%; p = .038, plogrank = 0.025), stroke (7.1 vs. 2.7%; p = .033), and major vascular complications (MVASC) (6.6 vs. 2.7%; p = .050) were more frequent in HA. Pronounced calcification of the noncoronary cusp and left ventricular outflow tract, the condition of HA, as well as repositioning maneuvers were independent predictors for overall specific AE. CONCLUSION: An HA above 51° is associated with an increased rate of stroke, MVASC, and 30-day mortality. Valve size and asymmetric calcification affect the incidence of repositioning maneuvers and subsequent VARC-2 AE, indicating that an HA-together with specific anatomic features-remains a crucial factor for TAVR-related outcome with self-expandable new-generation devices.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Aorta / Válvula Aórtica / Estenosis de la Válvula Aórtica / Prótesis Valvulares Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter / Hemodinámica Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Aorta / Válvula Aórtica / Estenosis de la Válvula Aórtica / Prótesis Valvulares Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter / Hemodinámica Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Alemania