Your browser doesn't support javascript.
loading
Ciliary muscle dimensions measured by swept-source optical coherence tomography in eyes with primary open-angle glaucoma and healthy eyes.
Kudsieh, Bachar; Fernández-Vigo, José Ignacio; Shi, Hang; De Pablo Gómez de Liaño, Lucía; Ruiz-Moreno, José María; García-Feijóo, Julián; Fernández-Vigo, José Ángel.
Afiliación
  • Kudsieh B; Department of Ophthalmology, Hospital Universitario Puerta de Hierro Majadahonda, Madrid, Spain. bacharkudsieh@gmail.com.
  • Fernández-Vigo JI; Centro Internacional de Oftalmología Avanzada, Zurbano 71, 28010, Madrid, Spain. bacharkudsieh@gmail.com.
  • Shi H; Centro Internacional de Oftalmología Avanzada, Zurbano 71, 28010, Madrid, Spain.
  • De Pablo Gómez de Liaño L; Department of Ophthalmology, San Carlos Clinical Hospital, Health Research Institute (IdISSC), Universidad Complutense, OFTARED, Madrid, Spain.
  • Ruiz-Moreno JM; Centro Internacional de Oftalmología Avanzada, Zurbano 71, 28010, Madrid, Spain.
  • García-Feijóo J; Department of Ophthalmology, San Carlos Clinical Hospital, Health Research Institute (IdISSC), Universidad Complutense, OFTARED, Madrid, Spain.
  • Fernández-Vigo JÁ; Department of Ophthalmology, Hospital Universitario Doce De Octubre, Madrid, Spain.
Int Ophthalmol ; 40(9): 2247-2255, 2020 Sep.
Article en En | MEDLINE | ID: mdl-32388672
ABSTRACT

PURPOSE:

To compare in vivo swept-source optical coherence tomography (SS-OCT) measurements of the ciliary muscle (CM) in patients with primary open-angle glaucoma (POAG) and healthy subjects, and examine correlations between CM dimensions and several covariates.

METHODS:

This was a cross-sectional study of the right eyes of 181

subjects:

89 POAG patients and 92 healthy subjects. Using the Triton SS-OCT device (Topcon, Tokyo, Japan), CM length (CML), area (CMA) and thickness measured 1000 µm (CMT1), 2000 µm (CMT2) and 3000 µm (CMT3) from the scleral spur were determined in the temporal and nasal quadrants. POAG patients were subjected to visual field (VF) and peripapillary retinal nerve fiber layer (RNFL) assessment. CM dimensions were then assessed for correlation with VF mean defect (MD), mean RNFL thickness and intraocular pressure (IOP).

RESULTS:

Mean CMLs were 4325 ± 340 µm and 4195 ± 843 µm for the healthy subjects and POAG patients, respectively (p = 0.17). Mean CM thicknesses were CMT1 = 546 ± 56 µm, CMT2 = 326 ± 44 µm and CMT3 = 174 ± 16 µm in the healthy eyes versus CMT1 = 534 ± 108, CMT2 = 332 ± 99 and CMT3 = 183 ± 74 in the POAG eyes, with no significant differences detected (all p ≥ 0.25). In the temporal quadrant, mean CMA was 1.12 ± 0.29 mm2 and 1.15 ± 0.24 mm2 for the healthy and POAG subjects, respectively (p = 0.45). No correlations were observed between CM measurements and RNFL thickness (p ≥ 0.15), IOP or VF MD (p ≥ 0.14) in POAG subjects irrespective of glaucoma severity (p ≥ 0.19).

CONCLUSIONS:

While SS-OCT proved useful to measure CM dimensions in vivo, these dimensions did not differ between healthy individuals and POAG subjects. In the patients with POAG, no correlations were detected between CM dimensions and VF, RNFL or IOP.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Disco Óptico / Glaucoma de Ángulo Abierto Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Humans País/Región como asunto: Asia Idioma: En Revista: Int Ophthalmol Año: 2020 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Disco Óptico / Glaucoma de Ángulo Abierto Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Humans País/Región como asunto: Asia Idioma: En Revista: Int Ophthalmol Año: 2020 Tipo del documento: Article País de afiliación: España