Your browser doesn't support javascript.
loading
Feasibility study of using simultaneous multi-slice RESOLVE diffusion weighted imaging to assess parotid gland tumors: comparison with conventional RESOLVE diffusion weighted imaging.
Jiang, Jia-Suo; Zhu, Liu-Ning; Wu, Qian; Sun, Yi; Liu, Wei; Xu, Xiao-Quan; Wu, Fei-Yun.
Afiliación
  • Jiang JS; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Nanjing, China.
  • Zhu LN; Department of Stomatology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Wu Q; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Nanjing, China.
  • Sun Y; MR Collaboration, Siemens Healthcare Ltd., Shanghai, China.
  • Liu W; Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China.
  • Xu XQ; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Nanjing, China. xxq_njmu@163.com.
  • Wu FY; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Nanjing, China. wfy_njmu@163.com.
BMC Med Imaging ; 20(1): 93, 2020 08 06.
Article en En | MEDLINE | ID: mdl-32762734
BACKGROUND: To evaluate the feasibility of using simultaneous multi-slice (SMS) readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) to assess parotid gland tumors, compared with conventional RESOLVE DWI. METHODS: From September 2018 to December 2018, 20 consecutive patients with parotid tumors who underwent MRI scan for pre-surgery evaluation were enrolled. SMS-RESOLVE DWI and conventional RESOLVE DWI were scanned with matched imaging parameters, respectively. The scan time of two DWI sequences was recorded. Qualitative (anatomical structure differentiation, lesion display, artifact, and overall image quality) and quantitative (apparent diffusion coefficient, ADC; ratio of signal-to-noise ratio, SNR ratio; ratio of contrast-to-noise ratio, CNR ratio) assessments of image quality were performed, and compared between SMS-RESOLVE DWI and conventional RESOLVE DWI by using Paired t-test. Two-sided P value less than 0.05 indicated significant difference. RESULTS: The scan time was 3 min and 41 s for SMS-RESOLVE DWI, and 5 min and 46 s for conventional RESOLVE DWI. SMS-RESOLVE DWI produced similar qualitative image quality with RESOLVE DWI (anatomical structure differentiation, P = 0.164; lesion display, P = 0.193; artifact, P = 0.330; overall image quality, P = 0.083). Meanwhile, there were no significant difference on ADCLesion (P = 0.298), ADCMasseter (P = 0.122), SNR ratio (P = 0.584) and CNR ratio (P = 0.217) between two DWI sequences. CONCLUSION: Compared with conventional RESOLVE DWI, SMS-RESOLVE DWI could provide comparable image quality using markedly reduced scan time. SMS could increase the clinical usability of RESOLVE technique for DWI of parotid gland.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Neoplasias de la Parótida / Interpretación de Imagen Radiográfica Asistida por Computador / Imagen Eco-Planar / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Observational_studies / Qualitative_research Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Med Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2020 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Neoplasias de la Parótida / Interpretación de Imagen Radiográfica Asistida por Computador / Imagen Eco-Planar / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Observational_studies / Qualitative_research Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Med Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2020 Tipo del documento: Article País de afiliación: China