Your browser doesn't support javascript.
loading
Determination of rare earth elements in Fe-minerals using external calibration by LA-ICP-MS and application on Cauê Iron Formation (Brazil).
Sousa, Denise V M; Abreu, Adriana T; Sampaio, Geraldo M S; Lana, Cristiano C; Rodrigues, Daniel A S; Nalini, Hermínio A.
Afiliación
  • Sousa DVM; Department of Geology, Federal University of Ouro Preto, Ouro Preto, 35400-000, Minas Gerais, Brazil; Department of Chemistry, Federal University of Minas Gerais, Belo Horizonte, 31270-901, Minas Gerais, Brazil. Electronic address: deniseversiane@gmail.com.
  • Abreu AT; Department of Geology, Federal University of Ouro Preto, Ouro Preto, 35400-000, Minas Gerais, Brazil. Electronic address: adrianatropia@gmail.com.
  • Sampaio GMS; Department of Geology, Federal University of Ouro Preto, Ouro Preto, 35400-000, Minas Gerais, Brazil. Electronic address: geraldomssampaio@gmail.com.
  • Lana CC; Department of Geology, Federal University of Ouro Preto, Ouro Preto, 35400-000, Minas Gerais, Brazil. Electronic address: cristiano.lana@ufop.edu.br.
  • Rodrigues DAS; Department of Geology, Federal University of Ouro Preto, Ouro Preto, 35400-000, Minas Gerais, Brazil. Electronic address: daniel00rodrigues@hotmail.com.
  • Nalini HA; Department of Geology, Federal University of Ouro Preto, Ouro Preto, 35400-000, Minas Gerais, Brazil. Electronic address: herminio.nalini@gmail.com.
Talanta ; 219: 121239, 2020 Nov 01.
Article en En | MEDLINE | ID: mdl-32887130
ABSTRACT
The rare earth elements (REE) composition in Fe-mineral phases is an important tool in iron formation studies to obtain information about parent rocks and environmental and paragenetic processes. However, the determination of REE presents some difficulties, such as the low concentration of these elements, matrix complexity and lack of iron matrix certified reference materials. The aim of the present work is to propose an analytical method to determine the REE plus Y (REE + Y) contents at trace levels in Fe-(hydr)oxides by the laser ablation ICP-quadrupoleMS technique, using external calibration. The calibration curves were obtained from analyses of reference materials with different matrices, and the analytical conditions were checked on the NIST 614 glass. The linearity (R2 ≥ 0.98), limit of detection (0.002-0.044 µg g-1), limit of quantification (0.008-0.146 µg g-1), recovery (88.4-112.4%), and intraday (0.1-14.1%) and interday (1.6-17.8%) precision were systematically assessed. The results obtained showed that the method is fit for the purpose and showed evidence of a nonsignificant interference of the matrix. Thus, the developed procedure was applied in the analyses of magnetite, martite, hematite, and goethite grains from Cauê Iron Formation (Brazil). The REE + Y patterns of the minerals are consistent with the previous study of bulk analyses on whole rocks and highlight the postdepositional signature of these elements in banded iron formations.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Prognostic_studies País/Región como asunto: America do sul / Brasil Idioma: En Revista: Talanta Año: 2020 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Prognostic_studies País/Región como asunto: America do sul / Brasil Idioma: En Revista: Talanta Año: 2020 Tipo del documento: Article