Your browser doesn't support javascript.
loading
Individual patient data analysis of the BIOFLOW study program comparing safety and efficacy of a bioresorbable polymer sirolimus eluting stent to a durable polymer everolimus eluting stent.
Toelg, Ralph; Slagboom, Ton; Waltenberger, Johannes; Lefèvre, Thierry; Saito, Shigeru; Kandzari, David E; Koolen, Jacques; Richardt, Gert.
Afiliación
  • Toelg R; Herzzentrum, Segeberger Kliniken GmbH, Bad Segeberg, Germany.
  • Slagboom T; Heartcenter, OLVG, Amsterdam, The Netherlands.
  • Waltenberger J; Klinik für Innere Med. I, SRH Zentralklinikum Suhl gGmbH, Suhl, Germany.
  • Lefèvre T; Hospital Privé Jacques Cartier, Massy, France.
  • Saito S; Department of Cardiology, Okinawa Tokushukai Shonan Kamakura General Hospital, Kamakura, Japan.
  • Kandzari DE; Piedmont Heart Institute, Atlanta, Georgia, USA.
  • Koolen J; Catharina Hospital, Eindhoven, The Netherlands.
  • Richardt G; Herzzentrum, Segeberger Kliniken GmbH, Bad Segeberg, Germany.
Catheter Cardiovasc Interv ; 98(5): 848-856, 2021 11 01.
Article en En | MEDLINE | ID: mdl-32890442
ABSTRACT

OBJECTIVES:

This analysis of pooled individual patient data (IPD) aimed to evaluate the safety and efficacy of a bioresorbable polymer sirolimus eluting stent system (BP-SES; Orsiro) compared to a durable polymer everolimus eluting stent system (DP-EES; Xience) in the pooled population as well as in subgroups.

METHODS:

IPD with up to 12 months follow-up of the randomized controlled trials BIOFLOW-II (NCT01356888), -IV (NCT01939249), and -V (NCT02389946) as well as the all comers registry BIOFLOW-III (NCT01553526) were pooled. A total of 3,717 subjects (2,923 in BP-SES and 794 in DP-EES) with 5,328 lesions (4,225 lesions in BP-SES and 1,103 in DP-EES) were included in the IPD. The primary endpoint was target lesion failure (TLF) at 12 months follow-up. Subgroups analyzed included diabetes, age (≥65 years), gender, complex lesions (B2/C), small vessels (reference vessel diameter ≤2.75 mm), multivessel treatment, renal disease, and patients with acute coronary syndrome.

RESULTS:

Overall, TLF at 12 months was significantly lower with 5.2%in the BP-SES group versus 7.6% in the DP-EES group (p = .0098). Similarly, target vessel myocardial infarction (TV-MI) was 3.1 versus 5.7% (p = .0005). The rate of stent thrombosis was similar in both groups (0.004%). By regression analysis, an independent stent effect in favor of BP-SES was observed for TLF (p = .0043) and TV-MI (p = .0364) in small vessels.

CONCLUSION:

Results of this IPD analysis suggest that the BP-SES with ultrathin struts is as safe as and more efficacious than DP-EES in the overall cohort and especially in small vessels.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Sirolimus / Stents Liberadores de Fármacos / Everolimus Tipo de estudio: Clinical_trials Límite: Aged / Humans Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Sirolimus / Stents Liberadores de Fármacos / Everolimus Tipo de estudio: Clinical_trials Límite: Aged / Humans Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania