Your browser doesn't support javascript.
loading
Antibody Micropatterned Lubricant-Infused Biosensors Enable Sub-Picogram Immunofluorescence Detection of Interleukin 6 in Human Whole Plasma.
Shakeri, Amid; Jarad, Noor Abu; Terryberry, Jeff; Khan, Shadman; Leung, Ashlyn; Chen, Simeng; Didar, Tohid F.
Afiliación
  • Shakeri A; Department of Mechanical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada.
  • Jarad NA; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada.
  • Terryberry J; SQI Diagnostics System Inc, 36 Meteor Dr, Toronto, ON M9W 1A4, Canada.
  • Khan S; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada.
  • Leung A; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada.
  • Chen S; SQI Diagnostics System Inc, 36 Meteor Dr, Toronto, ON M9W 1A4, Canada.
  • Didar TF; Department of Mechanical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada.
Small ; 16(45): e2003844, 2020 11.
Article en En | MEDLINE | ID: mdl-33078567
ABSTRACT
Recent studies have shown a correlation between elevated interleukin 6 (IL-6) concentrations and the risk of respiratory failure in COVID-19 patients. Therefore, detection of IL-6 at low concentrations permits early diagnosis of worst-case outcome in viral respiratory infections. Here, a versatile biointerface is presented that eliminates nonspecific adhesion and thus enables immunofluorescence detection of IL-6 in whole human plasma or whole human blood during coagulation, down to a limit of detection of 0.5 pg mL-1 . The sensitivity of the developed lubricant-infused biosensor for immunofluorescence assays in detecting low molecular weight proteins such as IL-6 is facilitated by i) producing a bioink in which the capture antibody is functionalized by an epoxy-based silane for covalent linkage to the fluorosilanized surface and ii) suppressing nonspecific adhesion by patterning the developed bioink into a lubricant-infused coating. The developed biosensor addresses one of the major challenges for biosensing in complex fluids, namely nonspecific adhesion, therefore paving the way for highly sensitive biosensing in complex fluids.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Interleucina-6 / Lubricantes / Microtecnología / Anticuerpos Tipo de estudio: Diagnostic_studies / Screening_studies Límite: Humans Idioma: En Revista: Small Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2020 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Interleucina-6 / Lubricantes / Microtecnología / Anticuerpos Tipo de estudio: Diagnostic_studies / Screening_studies Límite: Humans Idioma: En Revista: Small Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2020 Tipo del documento: Article País de afiliación: Canadá