Your browser doesn't support javascript.
loading
Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement.
Vidal-Petiot, Emmanuelle; Courbebaisse, Marie; Livrozet, Marine; Corrégé, Gwénaëlle; Rusu, Timofei; Montravers, Françoise; Baron, Stéphanie; Dupont, Léa; Balouzet, Clara; Smadja, Corinne; Leygnac, Sébastien; Pariscoat, Guillaume; Rose, Jimmy; Rouzet, François; Houillier, Pascal; Haymann, Jean-Philippe; Flamant, Martin.
Afiliación
  • Vidal-Petiot E; Université de Paris, Paris, France. emmanuelle.vidal-petiot@aphp.fr.
  • Courbebaisse M; Physiology Department, Assistance Publique-Hôpitaux de Paris, Hôpital Bichat, 46, rue Henri Huchard, 75018, Paris, France. emmanuelle.vidal-petiot@aphp.fr.
  • Livrozet M; Inserm U1149, Center for Research on Inflammation, Paris, France. emmanuelle.vidal-petiot@aphp.fr.
  • Corrégé G; Université de Paris, Paris, France.
  • Rusu T; Physiology Department, Assistance Publique-Hôpitaux de Paris, Hôpital européen Georges-Pompidou, 75015, Paris, France.
  • Montravers F; Institut Necker-Enfants Malades, INSERM U1151-CNRS UMR8253, Paris, France.
  • Baron S; Sorbonne Université, Paris, France.
  • Dupont L; Physiology Department, Assistance Publique-Hôpitaux de Paris, Hôpital Tenon, 75020, Paris, France.
  • Balouzet C; Department of Nuclear Medicine, Assistance Publique-Hôpitaux de Paris, Hôpital Tenon, 75020, Paris, France.
  • Smadja C; Department of Nuclear Medicine, Assistance Publique-Hôpitaux de Paris, Hôpital Tenon, 75020, Paris, France.
  • Leygnac S; Sorbonne Université, Paris, France.
  • Pariscoat G; Department of Nuclear Medicine, Assistance Publique-Hôpitaux de Paris, Hôpital Tenon, 75020, Paris, France.
  • Rose J; Université de Paris, Paris, France.
  • Rouzet F; Physiology Department, Assistance Publique-Hôpitaux de Paris, Hôpital européen Georges-Pompidou, 75015, Paris, France.
  • Houillier P; Centre de Recherche Des Cordeliers, INSERM, Université de Paris, 75006, Paris, France.
  • Haymann JP; Radiopharmacy Unit, Assistance Publique-Hôpitaux de Paris, Hôpital européen Georges-Pompidou, 75015, Paris, France.
  • Flamant M; Radiopharmacy Unit, Assistance Publique-Hôpitaux de Paris, Hôpital européen Georges-Pompidou, 75015, Paris, France.
J Nephrol ; 34(3): 729-737, 2021 06.
Article en En | MEDLINE | ID: mdl-33661505
ABSTRACT

PURPOSE:

The production of 51Cr-labelled ethylenediaminetetraacetic acid (51Cr-EDTA), a validated and widely used radio-isotopic tracer for glomerular filtration rate (GFR) measurement in Europe, was recently halted by the manufacturer. Technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) clearance has so far mostly been restricted to assessment of separate renal function by scintigraphy, but scarcely used and validated for GFR measurement. We compared the performances of 51Cr-EDTA and 99mTc-DTPA for GFR and extracellular fluid measurement.

METHODS:

In a multi-centre prospective study, 51Cr-EDTA and 99mTc-DTPA were simultaneously injected into 88 patients, and their urinary and plasma clearances, as well as their volumes of distribution, were measured during seven 30-min periods after a 90-min equilibrium time.

RESULTS:

Mean age was 52.2 ± 14.5 years, 59% were men. Urinary clearances of 51Cr-EDTA and 99mTc-DTPA were 64.1 ± 27.6 and 66.1 ± 28.0 mL/min, respectively, with a mean bias of 2.00 ± 2.25 mL/min, an accuracy within 10% of 95% [95% CI 91-99], and a coefficient of determination (R2) of 0.994. Plasma clearances of 51Cr-EDTA and 99mTc-DTPA were 66.1 ± 25.8 and 68.1 ± 26.6 mL/min, respectively, with a mean bias of 1.96 ± 3.32 mL/min, an accuracy within 10% of 91% [95% CI 85-97] and a R2 of 0.985. Distribution volumes were 17.3 ± 4.6 L for 51Cr-EDTA and 16.6 ± 4.6 L for 99mTc-DTPA (R2 0.930).

CONCLUSION:

The accuracy and precision of 99mTc-DTPA clearance, compared to 51Cr-EDTA clearance, was excellent for both urinary and plasma clearance methods, despite an approximate 2 mL/min overestimation, showing that the tracer is a reliable alternative to 51Cr-EDTA for GFR measurement.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Pentetato de Tecnecio Tc 99m / Tecnecio Tipo de estudio: Observational_studies Límite: Humans / Male / Middle aged Idioma: En Revista: J Nephrol Asunto de la revista: NEFROLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Pentetato de Tecnecio Tc 99m / Tecnecio Tipo de estudio: Observational_studies Límite: Humans / Male / Middle aged Idioma: En Revista: J Nephrol Asunto de la revista: NEFROLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Francia