Your browser doesn't support javascript.
loading
Field-effect pump: liquid dielectrophoresis along a virtual microchannel with source-gate-drain electric fields.
Wang, Fu-Min; Lu, I-Pei; Lin, Chih-Ting; Lu, Shey-Shi; Fan, Shih-Kang.
Afiliación
  • Wang FM; Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan.
  • Lu IP; Institute of Nanotechnology, National Chiao Tung University, Hsinchu 30010, Taiwan.
  • Lin CT; Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan.
  • Lu SS; Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan.
  • Fan SK; Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506, USA. skfan@ksu.edu.
Lab Chip ; 21(12): 2372-2382, 2021 06 15.
Article en En | MEDLINE | ID: mdl-34128001
ABSTRACT
We investigate liquid dielectrophoresis (LDEP) to implement field-effect pumps (FEPs) that drive liquids from source, via gate, toward drain electric fields between parallel plates without external pumps or the problem of dead volume. The appropriate gate electric field establishes a wall-less virtual microchannel to transfer the liquid from source to drain with an adjustable flow rate (Q) controlled by the difference of the square of the electric field strength (ΔE2DS). Analogous to field-effect transistors (FETs), the FEPs can operate in a "linear", "transition" or "saturation" region depending on ΔE2GD and ΔE2DS. With a sufficient ΔE2GD and a small ΔE2DS, the FEPs operated in the linear region where Q was linearly proportional to ΔE2DS and inversely proportional to the flow resistance R that was mainly determined by the length (L), width (W) and height (H) of a stable and fully-occupied virtual microchannel. With an insufficient ΔE2GD and a moderate to large ΔE2DS, narrowing, tapering and even pinch-off of virtual microchannels were observed, which increased R and changed the operation into the transition or saturation region. A field-effect stream merger regulating two streams was built based on two FEPs with shared gate and drain electrodes. The versatility of FEPs was demonstrated with preliminary studies on whole blood and particle solutions.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Electricidad Idioma: En Revista: Lab Chip Asunto de la revista: BIOTECNOLOGIA / QUIMICA Año: 2021 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Electricidad Idioma: En Revista: Lab Chip Asunto de la revista: BIOTECNOLOGIA / QUIMICA Año: 2021 Tipo del documento: Article País de afiliación: Taiwán