Your browser doesn't support javascript.
loading
Analysis of 18 complex diffuse arteriovenous malformation cases treated with percutaneous radiofrequency ablation.
Ge, Chun-Xiao; Tai, Mao-Zhong; Chen, Tao; Li, Ke-Lei; Xu, Zhen-Guo; Qin, Zhong-Ping.
Afiliación
  • Ge CX; Special Department of Vascular Anomalies, Linyi Cancer Hospital , No. 6 of Lingyuandong Street , Linyi, 276001, Shandong Province, China.
  • Tai MZ; Special Department of Vascular Anomalies, Linyi Cancer Hospital , No. 6 of Lingyuandong Street , Linyi, 276001, Shandong Province, China.
  • Chen T; Special Department of Vascular Anomalies, Linyi Cancer Hospital , No. 6 of Lingyuandong Street , Linyi, 276001, Shandong Province, China.
  • Li KL; Special Department of Vascular Anomalies, Linyi Cancer Hospital , No. 6 of Lingyuandong Street , Linyi, 276001, Shandong Province, China.
  • Xu ZG; Special Department of Vascular Anomalies, Linyi Cancer Hospital , No. 6 of Lingyuandong Street , Linyi, 276001, Shandong Province, China.
  • Qin ZP; Special Department of Vascular Anomalies, Linyi Cancer Hospital , No. 6 of Lingyuandong Street , Linyi, 276001, Shandong Province, China. qin_zhongpingcv@126.com.
BMC Cardiovasc Disord ; 21(1): 373, 2021 08 03.
Article en En | MEDLINE | ID: mdl-34344307
ABSTRACT

BACKGROUND:

The aim of the present study is to evaluate the short-term efficacy and feasibility of radiofrequency ablation in the treatment of complex diffuse arteriovenous (AV) malformations.

METHODS:

The data of 18 patients (8 male and 10 female) with complex AV malformations treated between December 2014 and June 2019 were analyzed retrospectively. The lesion area was 10 × 7 cm ~ 28 × 30 cm. Under duplex ultrasound guidance, the site with the most abundant blood flow signals in the lesion was percutaneously punctured with the radiofrequency ablation needle (electrode). The impedance automatic adjustment mode was adopted, and ablation was monitored usingduplex ultrasoundduring the entire process.

RESULTS:

Of the included patients, 1 had a high fever after two rounds of treatment, 2 had transient hemoglobinuria, and 1 had tissue necrosis in the original ruptured tumor area as well as a penetrating defect in the cheek, which was repaired with a pedicled trapezius myocutaneous flap. In 9 patients who experienced bleeding, the bleeding stopped after one round of treatment. During the follow-up period of 1-5 years, there were 0 grade I (poor) cases, 0 grade II (medium) cases, 7 grade III (good) cases, and 11 grade IV (excellent) cases.

CONCLUSION:

The "high power and continuous" radiofrequency ablation technique conducted under real-time duplex ultrasoundmonitoring can completely destroy the deep core lesions of AV malformations and effectively control life-threatening massive hemorrhage; it is an effective alternative treatment method for complex diffuse AV malformations in which interventional embolization, sclerotherapy, and surgery are ineffective.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Malformaciones Arteriovenosas / Ultrasonografía Intervencional / Ablación por Radiofrecuencia Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Cardiovasc Disord Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Malformaciones Arteriovenosas / Ultrasonografía Intervencional / Ablación por Radiofrecuencia Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Cardiovasc Disord Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: China