Your browser doesn't support javascript.
loading
Comparison of Photo-optical Transcutaneous Oxygen Tension Measurement with Electro-chemical Transcutaneous Oxygen Tension Measurement in Patients with Arterial Claudication.
Leenstra, Bernard Simon; Kuppens, Geoffrey Zinu Lukas; van Bergen, Annette; de Kleijn, Robert; de Borst, Gert J; Verhoeven, Bart.
Afiliación
  • Leenstra BS; Department of Vascular Surgery, UMC Utrecht, Utrecht, Christmas Island, The Netherlands. Electronic address: b.s.leenstra@umcutrecht.nl.
  • Kuppens GZL; Department of Vascular Surgery, Jeroen Bosch Ziekenhuis,'s-Hertogenbosch, Groningen, The Netherlands.
  • van Bergen A; Department of Vascular Surgery, Jeroen Bosch Ziekenhuis,'s-Hertogenbosch, Groningen, The Netherlands.
  • de Kleijn R; Department of Vascular Surgery, UMC Utrecht, Utrecht, Christmas Island, The Netherlands.
  • de Borst GJ; Department of Vascular Surgery, UMC Utrecht, Utrecht, Christmas Island, The Netherlands.
  • Verhoeven B; Department of Vascular Surgery, Jeroen Bosch Ziekenhuis,'s-Hertogenbosch, Groningen, The Netherlands.
Ann Vasc Surg ; 77: 274-279, 2021 Nov.
Article en En | MEDLINE | ID: mdl-34416286
ABSTRACT

PURPOSE:

Photo-optical TCpO2 (pTCpO2) has been proposed as a new method to determine the partial oxygen pressure of the lower extremity in patients with peripheral arterial disease. It is aimed to determine the level of agreement between pTCpO2 and the traditional electro-chemical transcutaneous oxygen tension measurement (eTCpO2).

METHODS:

Eighteen patients with intermittent claudication underwent simultaneous ankle-brachial index measurement, toe-pressure, pTCpO2 and eTCpO2 tests. Oxygen tension levels were measured on anterior chest and calf prior in rest (T0), during induced ischemia (T1) and after blood flow restoration (T2). TCpO2 agreement was assessed according to the principles of Bland and Altman.

RESULTS:

Absolute average TCpO2 values differed between eTCpO2 and pTCpO2 for calf in T2 (38,1 mmHg (σ 14,4) vs. 49,8 (σ 22.3) with P = 0.35). The Bland-Altman plots demonstrated eTCpO2 and pTCpO2 bias of 3,7 mmHg (σ 18,8), 11,6 mmHg (σ 17,6) and 6,7 mmHg (σ 23,5) for T0, T1 and T2 for the calf.

CONCLUSION:

pTCpO2 is in agreement with eTCpO2 in measuring pO2 levels of the lower extremity in rest and during induced ischemia in patients with vascular claudication. The large variability between eTCpO2 and pTCpO2 should be accounted for, while pTCpO2 values have a tendency to demonstrate higher values in comparison to eTCpO2.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Oxígeno / Fotometría / Piel / Monitoreo de Gas Sanguíneo Transcutáneo / Técnicas Electroquímicas / Enfermedad Arterial Periférica / Claudicación Intermitente Tipo de estudio: Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Vasc Surg Asunto de la revista: ANGIOLOGIA Año: 2021 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Oxígeno / Fotometría / Piel / Monitoreo de Gas Sanguíneo Transcutáneo / Técnicas Electroquímicas / Enfermedad Arterial Periférica / Claudicación Intermitente Tipo de estudio: Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Vasc Surg Asunto de la revista: ANGIOLOGIA Año: 2021 Tipo del documento: Article