Your browser doesn't support javascript.
loading
Functional calibration does not improve the concurrent validity of magneto-inertial wearable sensor-based thorax and lumbar angle measurements when compared with retro-reflective motion capture.
Cottam, Daniel S; Campbell, Amity C; Davey, Paul C; Kent, Peter; Elliott, Bruce C; Alderson, Jacqueline A.
Afiliación
  • Cottam DS; Australian Institute of Sport, Leverrier St, Bruce, 2602, Australian Capital Territory, Australia. daniel.cottam@ausport.gov.au.
  • Campbell AC; School of Physiotherapy and Exercise Science, Curtin University, Kent St, Bentley, Western Australia, 6102, Australia.
  • Davey PC; School of Physiotherapy and Exercise Science, Curtin University, Kent St, Bentley, Western Australia, 6102, Australia.
  • Kent P; School of Physiotherapy and Exercise Science, Curtin University, Kent St, Bentley, Western Australia, 6102, Australia.
  • Elliott BC; Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark.
  • Alderson JA; School of Human Sciences (Exercise and Sport Science), University of Western Australia, 35 Stirling Hwy, Crawley, Western Australia, 6009, Australia.
Med Biol Eng Comput ; 59(11-12): 2253-2262, 2021 Nov.
Article en En | MEDLINE | ID: mdl-34529184
 Magneto-inertial measurement unit (MIMU) systems allow calculation of simple sensor-to-sensor Euler angles, though this process does not address sensor-to-segment alignment, which is important for deriving meaningful MIMU-based kinematics. Functional sensor-to-segment calibrations have improved concurrent validity for elbow and knee angle measurements but have not yet been comprehensively investigated for trunk or sport-specific movements. This study aimed to determine the influence of MIMU functional calibration on thorax and lumbar joint angles during uni-planar and multi-planar, sport-specific tasks. It was hypothesised that functionally calibrating segment axes prior to angle decomposition would produce smaller differences than a non-functional method when both approaches were compared with concurrently collected 3D retro-reflective derived angles. Movements of 10 fast-medium cricket bowlers were simultaneously recorded by MIMUs and retro-reflective motion capture. Joint angles derived from four different segment definitions were compared, with three incorporating functionally defined axes. Statistical parametric mapping and root mean squared differences (RMSD) quantified measurement differences one-dimensionally and zero-dimensionally, respectively. Statistical parametric mapping found no significant differences between MIMU and retro-reflective data for any method across bowling and uni-planar trunk movements. The RMSDs for the functionally calibrated methods and non-functional method were not significantly different. Functional segment calibration may be unnecessary for MIMU-based measurement of thorax and lumbar joint angles.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Dispositivos Electrónicos Vestibles / Articulación de la Rodilla Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Med Biol Eng Comput Año: 2021 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Dispositivos Electrónicos Vestibles / Articulación de la Rodilla Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Med Biol Eng Comput Año: 2021 Tipo del documento: Article País de afiliación: Australia