Your browser doesn't support javascript.
loading
Safety and durability of cavo-tricuspid isthmus linear ablation in the current era: Single-center 9-year experience from 1078 procedures.
Kakehashi, Shota; Miyazaki, Shinsuke; Hasegawa, Kanae; Nodera, Minoru; Mukai, Moe; Aoyama, Daisetsu; Nagao, Moeko; Sekihara, Takayuki; Eguchi, Tomoya; Yamaguchi, Junya; Shiomi, Yuichiro; Tama, Naoto; Ikeda, Hiroyuki; Ishida, Kentaro; Uzui, Hiroyasu; Tada, Hiroshi.
Afiliación
  • Kakehashi S; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Miyazaki S; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Hasegawa K; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Nodera M; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Mukai M; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Aoyama D; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Nagao M; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Sekihara T; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Eguchi T; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Yamaguchi J; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Shiomi Y; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Tama N; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Ikeda H; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Ishida K; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Uzui H; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
  • Tada H; Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
J Cardiovasc Electrophysiol ; 33(1): 40-45, 2022 01.
Article en En | MEDLINE | ID: mdl-34676946
BACKGROUND: Cavo-tricuspid isthmus (CTI) linear ablation is performed not only for atrial flutter (AFL) but empirically during atrial fibrillation (AF) ablation in real-world practice.  PURPOSE: We sought to evaluate the safety and durability of the CTI ablation.  METHODS: This retrospective study included 1078 consecutive patients who underwent a CTI ablation. AFL was documented before or during the procedure in 249 (23.1%) patients, and an empirical CTI and AF ablation were performed in 829 (76.9%) patients.  RESULTS: CTI block was successfully created in 1051 (97.5%) patients with a 10.3 ± 6.6 min total radiofrequency time. Repeat procedures were performed for recurrent arrhythmias in 187 (17.3%) patients at a median of 11.0 (5.0-30.0) months postprocedure, and conduction resumption was identified in 68/174 (39.1%). Among those undergoing a CTI ablation with an AF ablation, the durability was significantly higher in those with than without documented AFL (78.1% vs. 58.2%, p = .031).  The total radiofrequency time was significantly shorter (9.0 ± 5.3 vs. 10.0 ± 6.4 [mins], p = .024) and durability significantly higher (78.1 vs. 58.7[%], p = .043) in the large-tip than irrigated-tip catheter group. Iatrogenic AFL was observed after the empiric CTI ablation in 11 (1.3%) patients. Procedure-related complications occurred in 15 (1.4%) patients. Eight patients experienced coronary artery spasms, including one with ventricular fibrillation following ST elevation on the ward. The other six patients experienced transient atrioventricular block and one experienced cardiac tamponade requiring drainage.  CONCLUSIONS: Despite a high acute CTI ablation success, the conduction block durability was relatively low after the empiric ablation. An empiric CTI ablation at the time of the AF ablation is not recommended.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Fibrilación Atrial / Aleteo Atrial / Ablación por Catéter Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Fibrilación Atrial / Aleteo Atrial / Ablación por Catéter Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Japón