Your browser doesn't support javascript.
loading
Posterior minimally invasive full-veneers: Effect of ceramic thicknesses, bonding substrate, and preparation designs on failure-load and -mode after fatigue.
Gierthmuehlen, Petra C; Jerg, Annika; Fischer, Johannes Benjamin; Bonfante, Estevam A; Spitznagel, Frank A.
Afiliación
  • Gierthmuehlen PC; Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
  • Jerg A; Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
  • Fischer JB; Private Practice, Gailingen, Germany.
  • Bonfante EA; Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of Sao Paulo, Bauru, Brazil.
  • Spitznagel FA; Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
J Esthet Restor Dent ; 34(1): 145-153, 2022 Jan.
Article en En | MEDLINE | ID: mdl-34989466
OBJECTIVE: To evaluate the effect of ceramic thicknesses, bonding surface (enamel vs. dentin), and preparation design (box vs. no box) on the fatigue survival and failure load of minimally invasive full-veneer restorations. MATERIALS AND METHODS: Human-premolars (n = 60) were divided into five test groups (n = 12). All teeth received full-veneer preparation with the following occlusal/labial thicknesses: standard: 1.5/0.8 mm; thin: 1.0/0.6 mm; ultrathin 0.5/0.4 mm. Preparations for each ceramic thickness were refined in enamel (E-1.0 and E-0.5) or dentin (D-1.5, D-1.0, and D-0.5). Control groups DB-1.5, EB-1.0, and EB-0.5 received box preparations. Monolithic lithium disilicate restorations (IPS-e.max-Press, Ivoclar Vivadent) were adhesively cemented (Syntac-Classic/Variolink-II, Ivoclar Vivadent) and subjected to cyclic mechanical loading (F = 49 N, 1.2 million cycles) with simultaneous thermocycling (5-55°C). All specimens were exposed to single load-to-failure. Pair-wise differences were calculated by using a linear regression model and Student-Newman-Keuls method (p < 0.05). RESULTS: All full-veneers of group D-1.5, E-1.0, E-0.5, DB-1.5, EB-1.0, and EB-0.5 survived fatigue. Two full-veneers (D-1.0 and D-0.5) revealed cracks during fatigue, resulting in an overall fatigue survival rate of 98.1%. Mean load-to-failure values (N) were as followed: 1005 (D-1.5); 866 (D-1.0); 816 (D-0.5); 1495 (E-1.0); 1279 (E-0.5); 1129 (DB-1.5); 1087 (EB-1.0); and 833 (EB-0.5). Irrespective of ceramic thicknesses, enamel-based full-veneers resulted in higher failure loads than dentin-based restorations. Box preparation reduced the failure loads of thin and ultrathin enamel-based restorations. CONCLUSION: All tested monolithic lithium disilicate full-veneer restorations exceeded physiological masticatory forces. Minimally invasive full-veneer restorations with enamel as a bonding surface and a non-retentive preparation design showed superior performance. CLINICAL SIGNIFICANCE: Enamel-based non-retentive full-veneers made of monolithic lithium disilicate may serve as a reliable and esthetical minimally invasive treatment option for premolars.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Porcelana Dental / Coronas con Frente Estético Límite: Humans Idioma: En Revista: J Esthet Restor Dent Asunto de la revista: ODONTOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Porcelana Dental / Coronas con Frente Estético Límite: Humans Idioma: En Revista: J Esthet Restor Dent Asunto de la revista: ODONTOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Alemania