Automated analysis of microplastics based on vibrational spectroscopy: are we measuring the same metrics?
Dong, Mingtan; She, Zhenbing; Xiong, Xiong; Ouyang, Guang; Luo, Zejiao.
Afiliación
  • Dong M; School of Environmental Studies, China University of Geosciences, Wuhan, 430078, China. hegu@cug.edu.cn.
  • She Z; State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, 430078, China.
  • Xiong X; School of Earth Sciences, China University of Geosciences, Wuhan, 430074, China.
  • Ouyang G; State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China.
  • Luo Z; Ministry of Natural Resources, Third Institute of Oceanography, Xiamen, 361005, China.
Anal Bioanal Chem ; 414(11): 3359-3372, 2022 May.
Article en En | MEDLINE | ID: mdl-35166866
ABSTRACT
The traditional manual analysis of microplastics has been criticized for its labor-intensive, inaccurate identification of small microplastics, and the lack of uniformity. There are already three automated analysis strategies for microplastics based on vibrational spectroscopy laser direct infrared (LDIR)-based particle analysis, Raman-based particle analysis, and focal plane array-Fourier transform infrared (FPA-FTIR) imaging. We compared their performances in terms of quantification, detection limit, size measurement, and material identification accuracy and speed by analyzing the same standard and environmental samples. LDIR-based particle analysis provides the fastest analysis speed, but potentially questionable material identification and quantification results. The number of particles smaller than 60 µm recognized by LDIR-based particle analysis is much less than that recognized by Raman-based particle analysis. Misidentification could occur due to the narrow tuning range from 1800 to 975 cm-1 and dispersive artifact distortion of infrared spectra collected in reflection mode. Raman-based particle analysis has a submicrometer detection limit but should be cautiously used in the automated analysis of microplastics in environmental samples because of the strong fluorescence interference. FPA-FTIR imaging provides relatively reliable quantification and material identification for microplastics in environmental samples greater than 20 µm but might provide an imprecise description of the particle shapes. Optical photothermal infrared (O-PTIR) spectroscopy can detect submicron-sized environmental microplastics (0.5-5 µm) intermingled with a substantial amount of biological matrix; the resulting spectra are searchable in infrared databases without the influence of fluorescence interference, but the process would need to be fully automated.