Cuffless and Touchless Measurement of Blood Pressure from Ballistocardiogram Based on a Body Weight Scale.
Liu, Shing-Hong; Zhang, Bing-Hao; Chen, Wenxi; Su, Chun-Hung; Chin, Chiun-Li.
Afiliación
  • Liu SH; Department of Computer Science and Information Engineering, Chaoyang University of Technology, Taichung City 41349, Taiwan.
  • Zhang BH; Department of Computer Science and Information Engineering, Chaoyang University of Technology, Taichung City 41349, Taiwan.
  • Chen W; Biomedical Information Engineering Laboratory, The University of Aizu, Aizu-Wakamatsu City 965-8580, Fukushima, Japan.
  • Su CH; Institute of Medicine, School of Medicine, Chung-Shan Medical University, Taichung City 40201, Taiwan.
  • Chin CL; Department of Internal Medicine, Chung-Shan Medical University Hospital, Taichung City 40201, Taiwan.
Nutrients ; 14(12)2022 Jun 20.
Article en En | MEDLINE | ID: mdl-35745282
ABSTRACT
Currently, in terms of reducing the infection risk of the COVID-19 virus spreading all over the world, the development of touchless blood pressure (BP) measurement has potential benefits. The pulse transit time (PTT) has a high relation with BP, which can be measured by electrocardiogram (ECG) and photoplethysmogram (PPG). The ballistocardiogram (BCG) reflects the mechanical vibration (or displacement) caused by the heart contraction/relaxation (or heart beating), which can be measured from multiple degrees of the body. The goal of this study is to develop a cuffless and touchless BP-measurement method based on a commercial weight scale combined with a PPG sensor when measuring body weight. The proposed method was that the PTTBCG-PPGT was extracted from the BCG signal measured by a weight scale, and the PPG signal was measured from the PPG probe placed at the toe. Four PTT models were used to estimate BP. The reference method was the PTTECG-PPGF extracted from the ECG signal and PPG signal measured from the PPG probe placed at the finger. The standard BP was measured by an electronic blood pressure monitor. Twenty subjects were recruited in this study. By the proposed method, the root-mean-square error (ERMS) of estimated systolic blood pressure (SBP) and diastolic blood pressure (DBP) are 6.7 ± 1.60 mmHg and 4.8 ± 1.47 mmHg, respectively. The correlation coefficients, r2, of the proposed model for the SBP and DBP are 0.606 ± 0.142 and 0.284 ± 0.166, respectively. The results show that the proposed method can serve for cuffless and touchless BP measurement.