Your browser doesn't support javascript.
loading
The anti-COVID-19 drug Favipiravir: Degradation, Method development, Validation, NMR/LC-MS characterization, and In-vitro safety evaluation.
Abdallah, Inas A; El-Behairy, Mohammed F; Ahmed, Rasha M; Fayed, Marwa A A.
Afiliación
  • Abdallah IA; Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, 32897 Egypt.
  • El-Behairy MF; Department of Organic and Medicinal Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, 32897 Egypt.
  • Ahmed RM; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Misr International University, Cairo, Egypt.
  • Fayed MAA; Department of Pharmacognosy, Faculty of Pharmacy, University of Sadat City, Sadat City, 32897 Egypt.
Chem Zvesti ; 76(10): 6415-6426, 2022.
Article en En | MEDLINE | ID: mdl-35812721
ABSTRACT
It is critical to characterize the degradation products of therapeutic drugs to determine their safety as these degradation products may possess fatal effects on the human physiological system. Favipiravir (FVP), a novel anti-Covid-19 drug, that is recently used all over the world with a great impact on humanity was our target to explore more about its toxicity, the margins of its safety, and its degradants in different degradation conditions. The goal of this study is to identify, characterize, and confirm the structures of FVP oxidative and alkaline breakdown products, as well as to assess their safety utilizing in-vitro SRB cytotoxicity assay on normal human skin fibroblasts (NHSF) cell lines. After oxidative and alkaline degradation of FVP, one degradation product was produced in each condition which was isolated from FVP using flash chromatography, characterized by 1HNMR and LC-MS/MS techniques. A reversed-phase Thermo Fischer Hypersil C18 column (4.6 × 150 mm, 5 m) was used to achieve HPLC chromatographic separation. Acetonitrile-5 mM potassium dihydrogen phosphate (pH 2.5) (5050, v/v) was employed as the mobile phase, with a flow rate of 1 mL/min. At 332 nm, the column effluent was measured. Over the concentration range of 0.5-100 µg/mL, the calibration curve was linear. The intra-day and inter-day relative standard deviations were less than 2%, and good percentage recoveries were obtained that fulfilled the acceptance criteria of the International Conference on Harmonization (ICH) recommendations. The Plackett-Burman design was used to assess the robustness. Each degradant was isolated single using Flash chromatography and methylene chloride methanol gradient mobile phase. The chemical structures of the degradation products have been confirmed and compared to the intact FVP using 1H-NMR, and Mass spectroscopy. A postulated mechanism of the degradation process has been depicted and the degradants fragmentation pattern has been portrayed. In addition, the in vitro SRB cytotoxicity assay to evaluate the safety profile of FVP and the degradation end products showed their high safety margin in both conditions with IC50 ˃100 µg/ml with no signs of toxicity upon examination of the treated NHSF cells under the optical microscope.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Guideline / Prognostic_studies Idioma: En Revista: Chem Zvesti Año: 2022 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Guideline / Prognostic_studies Idioma: En Revista: Chem Zvesti Año: 2022 Tipo del documento: Article