Influence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implant.
Matos, Jefferson David Melo de; Lopes, Guilherme da Rocha Scalzer; Queiroz, Daher Antonio; Pereira, André Luiz Jesus; Sinhoreti, Mário Alexandre Coelho; Ramos, Nathália de Carvalho; Lino, Vinicius; de Oliveira, Flavio Rosa; Borges, Alexandre Luiz Souto; Bottino, Marco Antonio.
Afiliación
  • Matos JDM; Department of Restorative Dental Sciences, Center for Dental Biomaterials, University of Florida (UF Health), Gainesville, FL 32601, USA.
  • Lopes GDRS; Department of Biomaterials, Dental Materials, and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos 12228-900, SP, Brazil.
  • Queiroz DA; Department of Biomaterials, Dental Materials, and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos 12228-900, SP, Brazil.
  • Pereira ALJ; Department of Restorative Dentistry & Prosthodontics, School of Dentistry, The University of Texas Health Science Center at Houston (UTHealth), Houston, TX 77054, USA.
  • Sinhoreti MAC; Plasmas and Processes Laboratory, Physics Departament, Aeronautics Technological Institute (ITA), 50 Marechal Eduardo Gomes Square, São José dos Campos 12228-900, SP, Brazil.
  • Ramos NC; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School (FOP-UNICAMP), Piracicaba 13416-000, SP, Brazil.
  • Lino V; Department of Biomaterials, Dental Materials, and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos 12228-900, SP, Brazil.
  • de Oliveira FR; Department of Dentistry, Universidade São Francisco (USF), Bragança Paulista 12916-900, SP, Brazil.
  • Borges ALS; Department of Dentistry, Postgraduate Program in Dentistry, University of Taubaté (UNITAU), Taubaté 12080-000, SP, Brazil.
  • Bottino MA; Department of Biomaterials, Dental Materials, and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos 12228-900, SP, Brazil.
Materials (Basel) ; 15(22)2022 Nov 16.
Article en En | MEDLINE | ID: mdl-36431619
ABSTRACT
The present study aimed to evaluate the biomechanical behavior of PEEK abutments with different heights on single titanium implants. To investigate the implant surface, different tests (scanning electron microscopy, energy-dispersive X-ray, and X-ray diffraction) were adopted. Herein, 20 implants received the 4.5 × 4.0 mm PEEK short abutment (SA) and 20 received the 4.5 × 5.5 mm PEEK long abutment (LA). The abutments were installed using dual-cure resin cement. To determine the fatigue test, two specimens from each group were submitted to the single load fracture test. For this, the samples were submitted to a compressive load of (0.5 mm/min; 30°) in a universal testing machine. For the fatigue test, the samples received 2,000,000 cycles (2 Hz; 30°). The number of cycles and the load test was analyzed by the reliability software SPSS statistics using Kaplan-Meier and Mantel-Cox tests (log-rank) (p < 0.05). The maximum load showed no statistically significant differences (p = 0.189) for the SA group (64.1 kgf) and the LA group (56.5 kgf). The study groups were statistically different regarding the number of cycles (p = 0.022) and fracture strength (p = 0.001). PEEK abutments can be indicated with caution for implant-supported rehabilitation and may be suitable as temporary rehabilitation.