Your browser doesn't support javascript.
loading
Fibrillar matrix, Echogenicity, Contour, Thickness, and Suture (FECTS) vs. Global: A comparison of 2 scales developed to assess ultrasound images post rotator cuff repair.
Williams, Tiffany G; Hackett, Lisa M; Lam, Patrick H; Stitz, Daniel J; Al-Housni, Hilal; Murrell, Dedee F; Murrell, George A C.
Afiliación
  • Williams TG; Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, NSW, Australia.
  • Hackett LM; Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, NSW, Australia.
  • Lam PH; Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, NSW, Australia.
  • Stitz DJ; Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, NSW, Australia.
  • Al-Housni H; Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, NSW, Australia.
  • Murrell DF; Department of Dermatology, St. George Hospital, Sydney, NSW, Australia.
  • Murrell GAC; Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, NSW, Australia. Electronic address: murrell.g@ori.org.au.
J Shoulder Elbow Surg ; 32(4): 713-728, 2023 Apr.
Article en En | MEDLINE | ID: mdl-36481456
ABSTRACT

BACKGROUND:

Ultrasound is commonly used to assess rotator cuff repair (RCR), but no standardized criterion exists to characterize the tendon.

PURPOSE:

The aims of this study were to (1) develop content validity for ultrasound specific criteria to grade the postoperative appearance of a tendon after RCR, (2) assess the reliability of the criteria, and (3) assess the feasibility to use these assessments.

METHODOLOGY:

Following expert consultation and literature review for content validity, 2 scales were created 1) the Fibrillar matrix, Echogenicity, Contour, Thickness, and Suture (FECTS) scale and 2) the Rotator Cuff Repair-Investigator Global Assessment (RCR-IGA). A prospective cohort study was undertaken on patients who had received a RCR and serial B-mode ultrasound images. Four raters assessed the 64-ultrasound images using the scales created in a blinded fashion using intraclass correlation coefficients.

RESULTS:

The FECTS scale was a composite score with 5 key parameters and the RCR-IGA scale was a 5-point global score. The intrarater reliability for the FECTS scale was excellent for the most experienced rater (0.92) and fair for the rater with no experience (0.72). The intrarater reliability for the RCR-IGA scale was excellent for 3 of the 4 raters (0.80-0.87) and fair when used by the least experienced rater (0.56). Inter-rater testing for all the FECTS scale parameters had excellent reliability (0.82-0.92) except for Fibrillar matrix (0.73). The average time to complete the FECTS scale per image was 23 seconds and 11 seconds for the RCR-IGA scale.

CONCLUSION:

The FECTS scale and the RCR-IGA scale are reliable tools to assess the ultrasonic appearance of the repaired rotator cuff tendon. The FECTS scale was more reliable for less experienced assessors. The RCR-IGA scale was easier, more time efficient and reliable for those with experience.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Lesiones del Manguito de los Rotadores Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Shoulder Elbow Surg Asunto de la revista: ORTOPEDIA Año: 2023 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Lesiones del Manguito de los Rotadores Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Shoulder Elbow Surg Asunto de la revista: ORTOPEDIA Año: 2023 Tipo del documento: Article País de afiliación: Australia