Your browser doesn't support javascript.
loading
Continuous Finger-cuff versus Intermittent Oscillometric Arterial Pressure Monitoring and Hypotension during Induction of Anesthesia and Noncardiac Surgery: The DETECT Randomized Trial.
Kouz, Karim; Weidemann, Friederike; Naebian, Ashkan; Lohr, Anneke; Bergholz, Alina; Thomsen, Kristen K; Krause, Linda; Petzoldt, Martin; Moll-Khosrawi, Parisa; Sessler, Daniel I; Flick, Moritz; Saugel, Bernd.
Afiliación
  • Kouz K; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Weidemann F; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Naebian A; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Lohr A; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Bergholz A; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Thomsen KK; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Krause L; Institute of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Petzoldt M; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Moll-Khosrawi P; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Sessler DI; Department of Outcomes Research, Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio; and Outcomes Research Consortium, Cleveland, Ohio.
  • Flick M; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Saugel B; Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; and Outcomes Research Consortium, Cleveland, Ohio.
Anesthesiology ; 139(3): 298-308, 2023 09 01.
Article en En | MEDLINE | ID: mdl-37265355
ABSTRACT

BACKGROUND:

Finger-cuff methods allow noninvasive continuous arterial pressure monitoring. This study aimed to determine whether continuous finger-cuff arterial pressure monitoring helps clinicians reduce hypotension within 15 min after starting induction of anesthesia and during noncardiac surgery. Specifically, this study tested the hypotheses that continuous finger-cuff-compared to intermittent oscillometric-arterial pressure monitoring helps clinicians reduce the area under a mean arterial pressure of 65 mmHg within 15 min after starting induction of anesthesia and the time-weighted average mean arterial pressure less than 65 mmHg during noncardiac surgery.

METHODS:

In this single-center trial, 242 noncardiac surgery patients were randomized to unblinded continuous finger-cuff arterial pressure monitoring or to intermittent oscillometric arterial pressure monitoring (with blinded continuous finger-cuff arterial pressure monitoring). The first of two hierarchical primary endpoints was the area under a mean arterial pressure of 65 mmHg within 15 min after starting induction of anesthesia; the second primary endpoint was the time-weighted average mean arterial pressure less than 65 mmHg during surgery.

RESULTS:

Within 15 min after starting induction of anesthesia, the median (interquartile range) area under a mean arterial pressure of 65 mmHg was 7 (0, 24) mmHg × min in 109 patients assigned to continuous finger-cuff monitoring versus 19 (0.3, 60) mmHg × min in 113 patients assigned to intermittent oscillometric monitoring (P = 0.004; estimated location shift -6 [95% CI -15 to -0.3] mmHg × min). During surgery, the median (interquartile range) time-weighted average mean arterial pressure less than 65 mmHg was 0.04 (0, 0.27) mmHg in 112 patients assigned to continuous finger-cuff monitoring and 0.40 (0.03, 1.74) mmHg in 115 patients assigned to intermittent oscillometric monitoring (P < 0.001; estimated location shift -0.17 [95% CI -0.41 to -0.05] mmHg).

CONCLUSIONS:

Continuous finger-cuff arterial pressure monitoring helps clinicians reduce hypotension within 15 min after starting induction of anesthesia and during noncardiac surgery compared to intermittent oscillometric arterial pressure monitoring.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Hipotensión / Anestesia Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Humans Idioma: En Revista: Anesthesiology Año: 2023 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Hipotensión / Anestesia Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Humans Idioma: En Revista: Anesthesiology Año: 2023 Tipo del documento: Article País de afiliación: Alemania