Your browser doesn't support javascript.
loading
Determination of Anti-Xa Inhibitor Plasma Concentrations Using a Universal Edoxaban Calibrator.
Burger, Annika; Studt, Jan-Dirk; Mendez, Adriana; Alberio, Lorenzo; Fontana, Pierre; Wuillemin, Walter A; Schmidt, Adrian; Graf, Lukas; Gerber, Bernhard; Bovet, Cédric; Sauter, Thomas C; Binder, Nikolaus B; Nagler, Michael.
Afiliación
  • Burger A; Department of Clinical Chemistry, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.
  • Studt JD; Division of Medical Oncology and Hematology, University Hospital Zurich, University of Zurich, 8006 Zurich, Switzerland.
  • Mendez A; Institute for Laboratory Medicine, Kantonsspital Aarau, 5001 Aarau, Switzerland.
  • Alberio L; Service and Central Laboratory of Hematology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011 Lausanne, Switzerland.
  • Fontana P; Division of Angiology and Hemostasis, Geneva University Hospital, 1205 Geneva, Switzerland.
  • Wuillemin WA; Division of Hematology, Hematology Laboratory, Cantonal Hospital of Lucerne, University of Bern, 3012 Bern, Switzerland.
  • Schmidt A; Institute of Laboratory Medicine, Clinic of Medical Oncology and Hematology, Municipal City Hospital Zurich Triemli, 8063 Zurich, Switzerland.
  • Graf L; Centre for Laboratory Medicine, 9001 St. Gallen, Switzerland.
  • Gerber B; Clinic of Hematology, Oncology Institute of Southern Switzerland, 6500 Bellinzona, Switzerland.
  • Bovet C; Department of Clinical Chemistry, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.
  • Sauter TC; Department of Emergency Medicine, Inselspital, Bern University Hospital, 3010 Bern, Switzerland.
  • Binder NB; Technoclone Herstellung von Diagnostika und Arzneimitteln GmbH, 1230 Vienna, Austria.
  • Nagler M; Department of Clinical Chemistry, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.
Diagnostics (Basel) ; 13(12)2023 Jun 20.
Article en En | MEDLINE | ID: mdl-37371023
ABSTRACT
A universal calibrator for the determination of all anti-Xa inhibitors would support laboratory processes. We aimed to test the clinical performance of an anti-Xa assay utilizing a universal edoxaban calibrator to determine clinically relevant concentrations of all anti-Xa inhibitors. Following a pilot study, we enrolled 553 consecutive patients taking rivaroxaban, edoxaban, or apixaban from nine study centers in a prospective cross-sectional study. The Technochrom® anti-Xa assay was conducted using the Technoview® edoxaban calibrator. Using ultra-high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS), anti-Xa inhibitor drug concentrations were determined. Sensitivities and specificities to detect three clinically relevant drug concentrations (30 µgL-1, 50 µgL-1, 100 µgL-1) were determined. Overall, 300 patients treated with rivaroxaban, 221 with apixaban, and 32 with edoxaban were included. The overall correlation coefficient (rs) was 0.95 (95% CI 0.94, 0.96). An area under the receiver operating characteristic curve of 0.96 for 30 µgL-1, 0.98 for 50 µgL-1, and 0.99 for 100 µgL-1 was found. The sensitivities were 92.3% (95% CI 89.2, 94.6), 92.7% (89.4, 95.1), and 94.8% (91.1, 97.0), respectively (specificities 82.2%, 93.7%, and 94.4%). In conclusion, the clinical performance of a universal, edoxaban-calibrated anti-Xa assay was solid and most drug concentrations were predicted correctly.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Diagnostics (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Diagnostics (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Suiza