Your browser doesn't support javascript.
loading
Morphology of the Radial Attachment of the Radioulnar Ligament and Surrounding Landmarks.
Matsuura, Masanori; Sato, Kotaro; Murakami, Kenya; Takahashi, Gaku; Hiroshi, Hasegawa; Doita, Minoru.
Afiliación
  • Matsuura M; Department of Orthopaedic Surgery, Iwate Medical University, Iwate, Japan. Electronic address: m11im15u@gmail.com.
  • Sato K; Department of Orthopaedic Surgery, Iwate Medical University, Iwate, Japan.
  • Murakami K; Department of Orthopaedic Surgery, Iwate Medical University, Iwate, Japan.
  • Takahashi G; Department of Critical Care Medicine, Iwate Medical University, Iwate, Japan.
  • Hiroshi H; Department of Orthopaedic Surgery, Iwate Medical University, Iwate, Japan.
  • Doita M; Department of Orthopaedic Surgery, Iwate Medical University, Iwate, Japan.
J Hand Surg Am ; 48(11): 1114-1121, 2023 11.
Article en En | MEDLINE | ID: mdl-37676190
ABSTRACT

PURPOSE:

The triangular fibrocartilage complex (TFCC) is composed of dorsal and palmar radioulnar ligaments (RULs). A common injury pattern of the RUL is the avulsion of the ulnar insertion, which can be treated by arthroscopic or open repair. Although the general method of TFCC reconstruction is a tendon graft with a bone tunnel, detailed information regarding the radial attachment of the RUL is unclear. This study aimed to clarify the morphology of the radial attachments of the palmar radioulnar ligament (PRUL), dorsal radioulnar ligament (DRUL), and short radiolunate ligament (SRL) using three-dimensional imaging.

METHODS:

A total of 29 upper limbs (16 formalin-fixed and 13 embalmed by Thiel's embalming method) of Japanese cadavers were used. After gross observation, we marked the attachments of the PRUL, DRUL, and SRL using 0.7-mm diameter pins. We created three-dimensional images of the radius, outlining the PRUL, DRUL, and SRL attachments. The software application calculated the centers of the PRUL and DRUL attachments.

RESULTS:

The PRUL attachment was horizontally shaped. The center of the PRUL was 1.5 mm proximal and 5.8 mm radial to the tip of the palmar pyramid formed by the palmar cortex and the radioulnar and radiocarpal joint surfaces. The DRUL attachment was vertically shaped. The center of the DRUL was 2.0 mm proximal and 1.7 mm radial from the tip of the dorsal pyramid formed by the dorsal cortex and the radioulnar and radiocarpal joint surfaces. The length of the SRL was 9.2 mm. The SRL and PRUL were strongly conjoined.

CONCLUSIONS:

The anatomical center on the RUL attachment of the radius can be determined from osseous landmarks. CLINICAL RELEVANCE The findings of this study contribute to the understanding of RUL attachment to the distal radius and may assist surgeons in performing anatomical reconstruction of TFCC.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Radio (Anatomía) / Fibrocartílago Triangular Límite: Humans Idioma: En Revista: J Hand Surg Am Año: 2023 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Radio (Anatomía) / Fibrocartílago Triangular Límite: Humans Idioma: En Revista: J Hand Surg Am Año: 2023 Tipo del documento: Article