Your browser doesn't support javascript.
loading
Vanquishing the computational cost of passive gamma emission tomography simulations leveraging physics-aware reduced order modeling.
Cavallini, Nicola; Ferretti, Riccardo; Bostrom, Gunnar; Croft, Stephen; Fassi, Aurora; Mercurio, Giovanni; Nonneman, Stefan; Favalli, Andrea.
Afiliación
  • Cavallini N; European Commission, Joint Research Centre, Via Enrico Fermi, 21027, Ispra, VA, Italy.
  • Ferretti R; Engineering Ingegneria Informatica, Piazzale dell'Agricoltura, 00144, Rome, RM, Italy.
  • Bostrom G; European Commission, Joint Research Centre, Via Enrico Fermi, 21027, Ispra, VA, Italy.
  • Croft S; European Commission, Joint Research Centre, Via Enrico Fermi, 21027, Ispra, VA, Italy.
  • Fassi A; Lancaster University, Bailrigg, Lancaster, UK.
  • Mercurio G; European Commission, Joint Research Centre, Via Enrico Fermi, 21027, Ispra, VA, Italy.
  • Nonneman S; European Commission, Joint Research Centre, Via Enrico Fermi, 21027, Ispra, VA, Italy.
  • Favalli A; European Commission, Joint Research Centre, Via Enrico Fermi, 21027, Ispra, VA, Italy.
Sci Rep ; 13(1): 15034, 2023 Sep 12.
Article en En | MEDLINE | ID: mdl-37699911
ABSTRACT
Passive Gamma Emission Tomography (PGET) has been developed by the International Atomic Energy Agency to directly image the spatial distribution of individual fuel pins in a spent nuclear fuel assembly and determine potential diversion. The analysis and interpretation of PGET measurements rely on the availability of comprehensive datasets. Experimental data are expensive and limited, so Monte Carlo simulations are used to augment them. However, Monte Carlo simulations have a high computational cost to simulate the 360 angular views of the tomography. Similar challenges pervade numerical science. With the aim to create a large dataset of PGET simulated scenarios, we addressed the computational cost of Monte Carlo simulations by developing a physics-aware reduced order modeling approach. This approach combines a small subset of the 360 angular views (limited views approach) with a computationally inexpensive proxy solution (real-time forward model) that brings the essence of the physics to obtain a real-time high-fidelity solution at all angular views but at a fraction of the computational cost. The method's ability to reconstruct 360 views with accuracy from a limited set of angular views is demonstrated by testing its performance for different types of reactor fuel assemblies.

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Health_economic_evaluation Idioma: En Revista: Sci Rep Año: 2023 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Health_economic_evaluation Idioma: En Revista: Sci Rep Año: 2023 Tipo del documento: Article País de afiliación: Italia