Your browser doesn't support javascript.
loading
Graphene oxide-enhanced colorimetric detection of Mec A gene based on toehold-mediated strand displacement.
Guo, Zongkang; Fan, Xueting; Wang, Xiaoli; Zhou, Zhemin; Zhang, Yuting; Zhou, Nandi.
Afiliación
  • Guo Z; The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China.
  • Fan X; The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China.
  • Wang X; The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China.
  • Zhou Z; The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China. Electronic address: zhmzhou@jiangnan.edu.cn.
  • Zhang Y; The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China. Electronic address: yutingzhang@jiangnan.edu.cn.
  • Zhou N; The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China.
Anal Biochem ; 684: 115365, 2024 01 01.
Article en En | MEDLINE | ID: mdl-37914003
ABSTRACT
Mec A, as a representative gene mediating resistance to ß-lactam antibiotics in methicillin-resistant Staphylococcus aureus (MRSA), allows a new genetic analysis for the detection of MRSA. Here, a sensitive, prompt, and visual colorimetry is reported to detect the Mec A gene based on toehold-mediated strand displacement (TMSD) and the enrichment effect of graphene oxide (GO). The Mec A triggers to generate the profuse amount of signal units of single-stranded DNA (SG) composed of a long single-stranded base tail and a base head the tail can be adsorbed and enriched on the surface of GO; the head can form a G quadruplex structure to exert catalytic function towards 2,2'-azino-bis (3-ethylbenzthiazoline-6-sulphonic acid). Therefore, through the enrichment effect of GO, the signal units SG reflects different degrees of signal amplification on different substrates (such as aqueous solution or filter membrane). This strategy demonstrates a broad linear working range from 100 pM to 1.5 nM (solution) and 1 pM to 1 nM (filter membrane), with a low detection limit of 39.53 pM (solution) and 333 fM (filter membrane). Analytical performance in real samples suggests that this developed colorimetry is endowed with immense potential for clinical detection applications.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Staphylococcus aureus Resistente a Meticilina / Grafito Idioma: En Revista: Anal Biochem Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Staphylococcus aureus Resistente a Meticilina / Grafito Idioma: En Revista: Anal Biochem Año: 2024 Tipo del documento: Article País de afiliación: China