Dosimetric effect of rotational setup errors in volumetric modulated arc therapy and field-in-field treatment of left-sided breast cancer.
Heikkilä, Annele; Boman, Eeva; Rossi, Maija; Vanhanen, Antti; Mankinen, Mikko; Postema, Michiel; Koivumäki, Tuomas.
Afiliación
  • Heikkilä A; BioMediTech, Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, 33720 Tampere, Finland; Department of Medical Physics, Tampere University Hospital, P.O. Box 2000, 33521 Tampere, Finland. Electronic address: annele.heikkila@tuni.fi.
  • Boman E; Department of Medical Physics, Tampere University Hospital, P.O. Box 2000, 33521 Tampere, Finland; Department of Oncology, Tampere University Hospital, P.O. Box 2000, 33521 Tampere, Finland.
  • Rossi M; Department of Medical Physics, Tampere University Hospital, P.O. Box 2000, 33521 Tampere, Finland; Department of Oncology, Tampere University Hospital, P.O. Box 2000, 33521 Tampere, Finland.
  • Vanhanen A; Department of Medical Physics, Tampere University Hospital, P.O. Box 2000, 33521 Tampere, Finland; Department of Oncology, Tampere University Hospital, P.O. Box 2000, 33521 Tampere, Finland.
  • Mankinen M; Department of Medical Physics, Central Finland Health Care District, Hoitajantie 3, 40620, Jyväskylä, Finland.
  • Postema M; BioMediTech, Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, 33720 Tampere, Finland; School of Electrical and Information Engineering, University of the Witwatersrand, Johannesburg, 1 Jan Smutslaan, 2050 Braamfontein, South Africa.
  • Koivumäki T; Department of Medical Physics, Central Finland Health Care District, Hoitajantie 3, 40620, Jyväskylä, Finland.
Phys Med ; 117: 103203, 2024 Jan.
Article en En | MEDLINE | ID: mdl-38171219
ABSTRACT
Setup errors are an important factor in the dosimetric accuracy of radiotherapy delivery. In this study, we investigated how rotational setup errors influence the dose distribution in volumetric modulated arc therapy (VMAT) and tangential field-in-field (FiF) treatment of left-sided breast cancer with supraclavicular lymph node involvement in deep inspiration breath hold. Treatment planning computed tomography images and radiotherapy plans of 20 patients were collected retrospectively for the study. Rotational setup errors up to 3° were simulated by rotating the planning images, and the resulting dosimetric changes were calculated. With rotational setup errors up to 3°, the median decrease of V95% to clinical target volume was less than 0.8 percentage point in both VMAT and FiF plans. The dose distribution of the heart and left anterior descending artery was more stable with respect to rotations in VMAT plans compared to FiF plans. Correction of ≥1° setup errors is recommended due to increased doses to the heart and left anterior descending artery after 1° setup errors.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Radioterapia de Intensidad Modulada / Neoplasias de Mama Unilaterales Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2024 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Radioterapia de Intensidad Modulada / Neoplasias de Mama Unilaterales Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2024 Tipo del documento: Article