A low-cost miniature immunosensor for haemoglobin as a device for the future detection of gastrointestinal bleeding.
Demirhan, Alper; Chianella, Iva; Patil, Samadhan B; Khalid, Ata.
Afiliación
  • Demirhan A; Center for Electronic Warfare, Information and Cyber, Cranfield University, Defence Academy of the UK, Shrivenham SN6 8LA, UK. ata.khalid@cranfield.ac.uk.
  • Chianella I; Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Bedford MK43 0AL, UK.
  • Patil SB; School of Physics, Engineering and Technology, University of York, York YO10 5DD, UK.
  • Khalid A; York Biomedical Research Institute (YBRI), University of York, York YO10 5DD, UK.
Analyst ; 149(4): 1081-1089, 2024 Feb 12.
Article en En | MEDLINE | ID: mdl-38204338
ABSTRACT
Gastrointestinal bleeding (GIB) is a serious medical condition, which requires immediate attention to establish the cause of the bleeding. Here, we present the development of a miniaturised electrochemical impedance spectroscopy (EIS) device for the detection of GIB. The device performs EIS measurements up to 100 kHz. Following the development of an immunosensor for haemoglobin (Hb) on screen printed electrodes, the EIS device was used for detecting Hb as an early indication of bleeding. The sensor was able to detect Hb in a redox solution in a linear range between 5 µg mL-1 and 60 µg mL-1, with a limit of detection of 13.3 µg mL-1. It was also possible to detect Hb in simulated intestinal fluid, without the need for a redox solution, within a range of 10 µg mL-1 to 10 mg mL-1 with a limit of detection of 2.31 mg mL-1. The miniature EIS device developed in this work is inexpensive, with an estimated cost per unit of £30, and has shown a comparable performance to existing commercial tools, demonstrating its potential to be used in the future as an ingestible sensor to detect GIB. All these measurements were carried out in a purpose built flow cell with supporting hardware electronics outside the cell. Integration of the hardware and the sensing electrodes was demonstrated in pill form. This pill after integration sampling fluidics has potential to be used in detecting gastrointestinal bleeding.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Hemoglobina Falciforme / Técnicas Biosensibles Tipo de estudio: Diagnostic_studies / Health_economic_evaluation Límite: Humans Idioma: En Revista: Analyst Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Hemoglobina Falciforme / Técnicas Biosensibles Tipo de estudio: Diagnostic_studies / Health_economic_evaluation Límite: Humans Idioma: En Revista: Analyst Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido