Manifold-based denoising for Ferumoxytol-enhanced 3D cardiac cine MRI.
Andrews, Anna; Doctor, Pezad; Gaur, Lasya; Greil, F Gerald; Hussain, Tarique; Zou, Qing.
Afiliación
  • Andrews A; Department of Biomedical Engineering, Mercer University, Macon, USA.
  • Doctor P; Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA.
  • Gaur L; Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA.
  • Greil FG; Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA.
  • Hussain T; Department of Radiology, The University of Texas Southwestern Medical Center, Dallas, TX, USA.
  • Zou Q; Advanced Imaging Research Center, The University of Texas Southwestern Medical Center, Dallas, TX, USA.
Math Biosci Eng ; 21(3): 3695-3712, 2024 Feb 18.
Article en En | MEDLINE | ID: mdl-38549302
ABSTRACT
The two-dimensional (2D) cine cardiovascular magnetic resonance (CMR) technique is the reference standard for assessing cardiac function. However, one challenge with 2D cine is that the acquisition time for the whole cine stack is long and requires multiple breath holds, which may not be feasible for pediatric or ill patients. Though single breath-hold multi-slice cine may address the issue, it can only acquire low-resolution images, and hence, affect the accuracy of cardiac function assessment. To address these challenges, a Ferumoxytol-enhanced, free breathing, isotropic high-resolution 3D cine technique was developed. The method produces high-contrast cine images with short acquisition times by using compressed sensing together with a manifold-based method for image denoising. This study included fifteen patients (9.1 $ \pm $ 5.6 yrs.) who were referred for clinical cardiovascular magnetic resonance imaging (MRI) with Ferumoxytol contrast and were prescribed the 3D cine sequence. The data was acquired on a 1.5T scanner. Statistical analysis shows that the manifold-based denoised 3D cine can accurately measure ventricular function with no significant differences when compared to the conventional 2D breath-hold (BH) cine. The multiplanar reconstructed images of the proposed 3D cine method are visually comparable to the golden standard 2D BH cine method in terms of clarity, contrast, and anatomical precision. The proposed method eliminated the need for breath holds, reduced scan times, enabled multiplanar reconstruction within an isotropic data set, and has the potential to be used as an effective tool to access cardiovascular conditions.