Your browser doesn't support javascript.
loading
A comparative study of electropolymerization and photopolymerization for the determination of molnupiravir and their application in an electrochemical sensor via computationally designed molecularly imprinted polymers.
Cetinkaya, Ahmet; Unal, M Altay; Nazir, Hasan; Çorman, M Emin; Uzun, Lokman; Ozkan, Sibel A.
Afiliación
  • Cetinkaya A; Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey.
  • Unal MA; Graduate School of Health Sciences, Ankara University, Ankara, Turkey.
  • Nazir H; Stem Cell Institute, Ankara University, Ankara, Turkey.
  • Çorman ME; Faculty of Science, Department of Chemistry, Ankara University, Ankara, Turkey.
  • Uzun L; Gülhane Faculty of Pharmacy, Department of Biochemistry, University of Health Sciences, Ankara, Turkey.
  • Ozkan SA; Faculty of Science, Department of Chemistry, Hacettepe University, Ankara, Turkey.
Mikrochim Acta ; 191(5): 270, 2024 04 17.
Article en En | MEDLINE | ID: mdl-38630200
ABSTRACT
A comparative analysis of molecularly imprinted polymers based on different synthesis techniques was performed for the recognition of molnupiravir (MOL). The polymerizations were performed with 3-thienyl boronic acid (3-TBA) as a functional monomer by electropolymerization (EP) and with guanine methacrylate (GuaM) as a functional monomer by photopolymerization (PP). Morphological and electrochemical characterizations of the developed sensors were investigated to verify the constructed sensors. Moreover, quantum chemical calculations were used to evaluate changes on the electrode surface at the molecular and electronic levels. The dynamic linear range of both designed sensors under optimized experimental conditions was found to be 7.5 × 10-12-2.5 × 10-10 M and 7.5 × 10-13-2.5 × 10-11 M for EP and PP, respectively. The effect of various interfering agents on MOL peak current was assessed for the selectivity of the study. In the presence of 100 times more interfering agents, the RSD and recovery values were determined. The RSD values of GuaM/MOL@MIP/GCE and poly(Py-co-3-PBA)/MOL@MIP/GCE sensors were found to be 1.99% and 1.72%, respectively. Furthermore, the recovery values of the MIP-based sensors were 98.18-102.69% and 98.05-103.72%, respectively. In addition, the relative selectivity coefficient (k') of the proposed sensor was evaluated, and it exhibited good selectivity for MOL with respect to the NIP sensor. The prepared sensor was successfully applied to determine MOL in commercial serum samples and capsule form. In conclusion, the developed sensors provided excellent reproducibility, repeatability, high sensitivity, and selectivity against the MOL molecule.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ácidos Borónicos / Citidina / Polímeros Impresos Molecularmente / Hidroxilaminas Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ácidos Borónicos / Citidina / Polímeros Impresos Molecularmente / Hidroxilaminas Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: Turquía