Your browser doesn't support javascript.
loading
An institutional study on accuracy of freehand cervical C1 C2 screws placement by knock and drill technique in craniovertebral anomalous bony anatomy: An evaluation of more than 600 screws based on SGPGI screw accuracy criteria.
Sasapardhi, Sudhir Bisan; Verma, Pawan Kumar; Srivastava, Arun Kumar; Das, Kuntal Kanti; Kumar, Ashutosh; Dikshit, Priyadarshi; Maurya, Ved Prakash; Bhaisora, Kamlesh Singh; Mehrotra, Anant; Jaiswal, Awadhesh Kumar; Mishra, Prabhaker; Behari, Sanjay; Kumar, Raj; Mishra, Harshit; Shahare, Kalyani.
Afiliación
  • Sasapardhi SB; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Verma PK; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Srivastava AK; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Das KK; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Kumar A; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Dikshit P; Department of Neurosurgery, AIIMS, Guwahati, Assam, India.
  • Maurya VP; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Bhaisora KS; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Mehrotra A; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Jaiswal AK; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Mishra P; Department of Biostatistics and Health Informatics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Behari S; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Kumar R; Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Mishra H; Department of Neuroanesthesiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Shahare K; Department of Neuroanesthesiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
J Craniovertebr Junction Spine ; 15(1): 83-91, 2024.
Article en En | MEDLINE | ID: mdl-38644916
ABSTRACT

Purpose:

To assess the accuracy of freehand cervical C1 C2 screws placement by knock and drill (K and D) technique in craniovertebral anomalous bony anatomy. Materials and

Methods:

From January 2017 to December 2022, 682 consecutive C1 C2 screws in 215 patients with craniovertebral junction (CVJ) anomalies were enrolled. All patients underwent posterior fixation with K and D technique without any fluoroscopic guidance. The patient's demographic details, clinical details, radiological details, major intraoperative events, and postoperative complications were noted. The screws malposition grades and direction on CT images in the axial and sagittal plane were defined as new per proposed "SGPGI accuracy criteria." All patients had a clinical evaluation at 3-month follow-up.

Results:

Total 682 C1, C2 screws were placed in 215 patients for CVJ anomalies using K and D technique. The accuracy of screws placement by freehand technique was 84.46% (576/682). So with technique explained the rate of malplacement in simple (16.35%) and complex (15.19%) groups were almost comparable and comparison difference was not significant (P = 0.7005).

Conclusion:

The freehand technique, as described, is effective in cases of anomalous bony anatomy, and it is mandatory in complex CVJ anomalies. The accuracy of screw placement and VA injury is comparable with major studies. This technique is supposedly cost-effective and less hazardous to both health-care workers and patients.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Craniovertebr Junction Spine Año: 2024 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Craniovertebr Junction Spine Año: 2024 Tipo del documento: Article País de afiliación: India