Your browser doesn't support javascript.
loading
Post column infusion of an internal standard into LC-FT-ICR MS enables semi-quantitative comparison of dissolved organic matter in original samples.
Rodrigues Matos, Rebecca; Jennings, Elaine K; Kaesler, Jan; Reemtsma, Thorsten; Koch, Boris P; Lechtenfeld, Oliver J.
Afiliación
  • Rodrigues Matos R; Department of Environmental Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318 Leipzig, Germany. oliver.lechtenfeld@ufz.de.
  • Jennings EK; Department of Environmental Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318 Leipzig, Germany. oliver.lechtenfeld@ufz.de.
  • Kaesler J; Department of Environmental Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318 Leipzig, Germany. oliver.lechtenfeld@ufz.de.
  • Reemtsma T; Department of Environmental Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318 Leipzig, Germany. oliver.lechtenfeld@ufz.de.
  • Koch BP; Institute of Analytical Chemistry, University of Leipzig, 04103 Leipzig, Germany.
  • Lechtenfeld OJ; Alfred-Wegener-Institute Helmholtz Centre for Polar and Marine Research, Ecological Chemistry, Am Handelshafen 12, 27570 Bremerhaven, Germany.
Analyst ; 149(12): 3468-3478, 2024 Jun 10.
Article en En | MEDLINE | ID: mdl-38742449
ABSTRACT
Ultrahigh resolution mass spectrometry hyphenated with liquid chromatography (LC) is an emerging tool to explore the isomeric composition of dissolved organic matter (DOM). However, matrix effects limit the potential for semi-quantitative comparison of DOM molecule abundances across samples. We introduce a post-column infused internal standard (PCI-IS) for reversed-phase LC-FT-ICR MS measurements of DOM and systematically evaluate matrix effects, detector linearity and the precision of mass peak intensities. Matrix effects for model compounds spiked into freshwater DOM samples ranging from a headwater stream to a major river were reduced by 5-10% for PCI-IS corrected mass peak intensities as compared to raw (i.e., untransformed) intensities. A linear regression of PCI-IS corrected DOM mass peak intensities across a typical DOM concentration range (2-15 mg dissolved organic carbon L-1) in original, non-extracted freshwater samples demonstrates excellent linearity of the detector response (r2 > 0.9 for 98% of detected molecular formulas across retention times). Importantly, PCI-IS could compensate for 80% of matrix effects across an environmental gradient of DOM composition from groundwater to surface water. This enabled studying the ionization efficiency of DOM isomers and linking the observed differences to the biogeochemical sources. With PCI-IS original, non-extracted DOM samples can be analysed by LC-FT-ICR MS without carbon load adjustment, and mass peak intensities can be reliably used to semi-quantitatively compare isomer abundances between compositionally similar DOM samples.

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Analyst Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Analyst Año: 2024 Tipo del documento: Article País de afiliación: Alemania