Your browser doesn't support javascript.
loading
All-suture anchor size and drill angle influence load to failure in a porcine model of subpectoral biceps tenodesis, a biomechanical study.
Alt, Prisca S; Marx, Christian; Braun, Sepp.
Afiliación
  • Alt PS; Department of Handsurgery, University Hospital Basel, Basel, Switzerland.
  • Marx C; Research Unit for Orthopedic Sports Medicine and Injury Prevention, Medical Informatics and Technology, UMIT - Private University for Health Sciences, Hall in Tirol, 6060, Austria.
  • Braun S; Gelenkpunkt - Sports and Joint Surgery, Innsbruck, Austria. s.braun@gelenkpunkt.com.
BMC Musculoskelet Disord ; 25(1): 408, 2024 May 23.
Article en En | MEDLINE | ID: mdl-38783272
ABSTRACT

BACKGROUND:

Tenodesis of the long head of the biceps tendon is frequently performed in shoulder surgery, and all-suture anchors have become more popular as fixation methods. However, uncertainty still exists regarding the ultimate load to failure of all-suture anchors and the best insertion angle at a cortical humeral insertion point.

PURPOSE:

The purpose of this study was to compare the biomechanical characteristics of three types of all-suture anchors frequently used for biceps tenodesis. In addition, the influence of two different insertion angles was observed in a porcine humeri model.

METHODS:

The ultimate load to failure and failure mode of three types of all-suture anchors (1.6 FiberTak®, 1.9 FiberTak®, 2.6 FiberTak®, Arthrex®) applicable for subpectoral biceps tenodesis were evaluated at 90° and 45° insertion angles in 12 fresh-frozen porcine humeri. The anchors were inserted equally alternated in a randomized manner at three different insertion sites along the bicipital groove, and the suture tapes were knotted around a rod for pullout testing. In total, 36 anchors were evaluated in a universal testing machine (Zwick & Roell).

RESULTS:

The 2.6 FiberTak® shows higher ultimate loads to failure with a 90° insertion angle (944.0 N ± 169.7 N; 537.0 N ± 308.8 N) compared to the 1.9 FiberTak® (677.8 N ± 57.7 N; 426.3 N ± 167.0 N, p-value 0.0080) and 1.6 FiberTak® (733.0 N ± 67.6 N; 450.0 N ± 155.8 N, p-value 0.0018). All anchor types show significantly higher ultimate loads to failure and smaller standard deviations at the 90° insertion angle than at the 45° insertion angle. The major failure mode was anchor pullout. Only the 2.6 FiberTak® anchors showed suture breakage as the major failure mode when placed with a 90° insertion angle.

CONCLUSIONS:

All three all-suture anchors are suitable fixation methods for subpectoral biceps tenodesis. Regarding our data, we recommend 90° as the optimum insertion angle. CLINICAL RELEVANCE The influence of anchor size and insertion angle of an all-suture anchor should be known by the surgeon for optimizing ultimate loads to failure and for achieving a secure fixation.