Flexible Peripheral Nerve Interfacing Electrode for Joint Position Control in Closed-Loop Neuromuscular Stimulation.
Kim, Sia; Song, Kang-Il.
Afiliación
  • Kim S; Department of Biomedical Engineering, University of Ulsan, Ulsan 44610, Republic of Korea.
  • Song KI; Division of Smart Healthcare, Pukyung National University, Busan 48513, Republic of Korea.
Micromachines (Basel) ; 15(5)2024 Apr 29.
Article en En | MEDLINE | ID: mdl-38793167
ABSTRACT
Addressing peripheral nerve disorders with electronic medicine poses significant challenges, especially in replicating the dynamic mechanical properties of nerves and understanding their functionality. In the field of electronic medicine, it is crucial to design a system that thoroughly understands the functions of the nervous system and ensures a stable interface with nervous tissue, facilitating autonomous neural adaptation. Herein, we present a novel neural interface platform that modulates the peripheral nervous system using flexible nerve electrodes and advanced neuromodulation techniques. Specifically, we have developed a surface-based inverse recruitment model for effective joint position control via direct electrical nerve stimulation. Utilizing barycentric coordinates, this model constructs a three-dimensional framework that accurately interpolates inverse isometric recruitment values across various joint positions, thereby enhancing control stability during stimulation. Experimental results from rabbit ankle joint control trials demonstrate our model's effectiveness. In combination with a proportional-integral-derivative (PID) controller, it shows superior performance by achieving reduced settling time (less than 1.63 s), faster rising time (less than 0.39 s), and smaller steady-state error (less than 3 degrees) compared to the legacy model. Moreover, the model's compatibility with recent advances in flexible interfacing technologies and its integration into a closed-loop controlled functional neuromuscular stimulation (FNS) system highlight its potential for precise neuroprosthetic applications in joint position control. This approach marks a significant advancement in the management of neurological disorders with advanced neuroprosthetic solutions.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Micromachines (Basel) Año: 2024 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Micromachines (Basel) Año: 2024 Tipo del documento: Article