Your browser doesn't support javascript.
loading
Improved Diagnostic Accuracy of Thyroid Fine-Needle Aspiration Cytology with Artificial Intelligence Technology.
Lee, Yujin; Alam, Mohammad Rizwan; Park, Hongsik; Yim, Kwangil; Seo, Kyung Jin; Hwang, Gisu; Kim, Dahyeon; Chung, Yeonsoo; Gong, Gyungyub; Cho, Nam Hoon; Yoo, Chong Woo; Chong, Yosep; Choi, Hyun Joo.
Afiliación
  • Lee Y; Department of Hospital Pathology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, Republic of Korea.
  • Alam MR; Department of Hospital Pathology, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Republic of Korea.
  • Park H; Department of Hospital Pathology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, Republic of Korea.
  • Yim K; Department of Hospital Pathology, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Republic of Korea.
  • Seo KJ; Department of Hospital Pathology, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Republic of Korea.
  • Hwang G; AI Team, DeepNoid Inc., Seoul, Korea.
  • Kim D; AI Team, DeepNoid Inc., Seoul, Korea.
  • Chung Y; AI Team, DeepNoid Inc., Seoul, Korea.
  • Gong G; Department of Pathology, Asan Medical Center, Seoul, Korea.
  • Cho NH; Department of Pathology, Yonsei University College of Medicine, Seoul, Korea.
  • Yoo CW; Department of Pathology, National Cancer Center, Ilsan, Republic of Korea.
  • Chong Y; Department of Hospital Pathology, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Republic of Korea.
  • Choi HJ; Department of Hospital Pathology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon, Republic of Korea.
Thyroid ; 34(6): 723-734, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38874262
ABSTRACT

Background:

Artificial intelligence (AI) is increasingly being applied in pathology and cytology, showing promising results. We collected a large dataset of whole slide images (WSIs) of thyroid fine-needle aspiration cytology (FNA), incorporating z-stacking, from institutions across the nation to develop an AI model.

Methods:

We conducted a multicenter retrospective diagnostic accuracy study using thyroid FNA dataset from the Open AI Dataset Project that consists of digitalized images samples collected from 3 university hospitals and 215 Korean institutions through extensive quality check during the case selection, scanning, labeling, and reviewing process. Multiple z-layer images were captured using three different scanners and image patches were extracted from WSIs and resized after focus fusion and color normalization. We pretested six AI models, determining Inception ResNet v2 as the best model using a subset of dataset, and subsequently tested the final model with total datasets. Additionally, we compared the performance of AI and cytopathologists using randomly selected 1031 image patches and reevaluated the cytopathologists' performance after reference to AI results.

Results:

A total of 10,332 image patches from 306 thyroid FNAs, comprising 78 malignant (papillary thyroid carcinoma) and 228 benign from 86 institutions were used for the AI training. Inception ResNet v2 achieved highest accuracy of 99.7%, 97.7%, and 94.9% for training, validation, and test dataset, respectively (sensitivity 99.9%, 99.6%, and 100% and specificity 99.6%, 96.4%, and 90.4% for training, validation, and test dataset, respectively). In the comparison between AI and human, AI model showed higher accuracy and specificity than the average expert cytopathologists beyond the two-standard deviation (accuracy 99.71% [95% confidence interval (CI), 99.38-100.00%] vs. 88.91% [95% CI, 86.99-90.83%], sensitivity 99.81% [95% CI, 99.54-100.00%] vs. 87.26% [95% CI, 85.22-89.30%], and specificity 99.61% [95% CI, 99.23-99.99%] vs. 90.58% [95% CI, 88.80-92.36%]). Moreover, after referring to the AI results, the performance of all the experts (accuracy 96%, 95%, and 96%, respectively) and the diagnostic agreement (from 0.64 to 0.84) increased.

Conclusions:

These results suggest that the application of AI technology to thyroid FNA cytology may improve the diagnostic accuracy as well as intra- and inter-observer variability among pathologists. Further confirmatory research is needed.