Single-piece zirconia versus single-piece titanium, narrow-diameter dental implants in the anterior maxilla: 5-year post-loading results of a randomized clinical trial.
Ruiz Henao, Paula Andrea; Magrin, Gabriel Leonardo; Caneiro-Queija, Leticia; Benfatti, Cesar Augusto Magalhães; Leira, Yago; Liñares-González, Antonio; Blanco-Carrión, Juan.
Afiliación
  • Ruiz Henao PA; Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.
  • Magrin GL; Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.
  • Caneiro-Queija L; Center for Education and Research on Dental Implants (CEPID), Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil.
  • Benfatti CAM; Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.
  • Leira Y; Center for Education and Research on Dental Implants (CEPID), Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil.
  • Liñares-González A; Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.
  • Blanco-Carrión J; Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.
Article en En | MEDLINE | ID: mdl-38940623
ABSTRACT

OBJECTIVES:

The aim of this study was to evaluate esthetic parameters in the anterior maxillary region by comparing single-piece zirconia versus titanium narrow-diameter implants. Additionally, clinical, radiological and patient-reported outcome measures (PROMs) were analyzed. MATERIALS AND

METHODS:

Thirty implants (tissue level implant) were placed in 30 patients in the maxillary esthetic sector. Depending on randomization, a zirconia (test) or titanium implant (control) was placed. Esthetic, clinical, and radiological parameters, including the implant crown esthetic index (ICAI), pink esthetic score (PES), probing pocket depth, bleeding on probing, plaque index, and marginal bone levels, were evaluated at 12, 36 and 60 months after loading.

RESULTS:

Sixty months after crown placement, no significant differences were found between groups. The ICAI values were 5.25 ± 4.21 and 4.50 ± 2.98 for the test and control groups, respectively. The corresponding PES values were 7.44 ± 1.93 and 7.43 ± 1.74 for the test and control groups, respectively. There were no significant intergroup differences for the rest of the parameters evaluated.

CONCLUSION:

It can be suggested that monotype zirconia implants may serve as a potential alternative to titanium implants in selected clinical scenarios. While the results demonstrated comparable esthetic, clinical, and radiological aspects for zirconia implants as compared to titanium implants after a 5-year follow-up period, further research with larger sample sizes and longer-term follow-up is recommended.