Your browser doesn't support javascript.
loading
Baseline-to-loaded changes in regional tibial cartilage thickness, T1ρ and T2: Utilization of an MRI compatible loading device.
Argentieri, Erin C; Pekmezian, Ashley; Wach, Arden; Zhu, Andrew; Bansal, Sonia; Breighner, Ryan E; Leatherman, Erin R; Potter, Hollis G; Maher, Suzanne A; Koff, Matthew F.
Afiliación
  • Argentieri EC; Department of Radiology and Imaging, MRI Laboratory, Hospital for Special Surgery, New York City, New York, USA.
  • Pekmezian A; Department of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.
  • Wach A; Department of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.
  • Zhu A; Weill Cornell Medicine, Weill Cornell Medical College, New York City, New York, USA.
  • Bansal S; Department of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.
  • Breighner RE; Department of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.
  • Leatherman ER; Department of Mathematics and Statistics, Kenyon College, Gambier, Ohio, USA.
  • Potter HG; Department of Radiology and Imaging, MRI Laboratory, Hospital for Special Surgery, New York City, New York, USA.
  • Maher SA; Department of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.
  • Koff MF; Department of Radiology and Imaging, MRI Laboratory, Hospital for Special Surgery, New York City, New York, USA.
J Orthop Res ; 2024 Aug 23.
Article en En | MEDLINE | ID: mdl-39177306
ABSTRACT
The objective of the study was to evaluate tibial cartilage thickness (TCT), T1ρ and T2 values within both loaded and baseline configurations in a cadaveric knee model using a 3D bone based tibial coordinate system. Ten intact cadaveric knees were mounted into an magnetic resonance imaging (MRI) compatible loading device. Morphologic and quantitative MRI (qMRI) images were acquired with the knee in a baseline configuration and after application of 50% body weight. The morphologic images were evaluated for cartilage degeneration using a modified Noyes scoring system. A 3D bone-based tibial coordinate system was utilized to evaluate regional changes of tibial T1ρ, T2, and cartilage thickness values among regions covered and uncovered by the meniscus. Inter-regional differences in medial and lateral MRI outcomes were found between loaded and baseline configurations. Cartilage regions covered by the meniscus demonstrated disparate qMRI and TCT results as compared to cartilage regions not covered by the meniscus. The regions covered by meniscus experienced a ~3.5%, ~0.5%, and ~5.5% reduction of T1ρ (p < 0.05, medial and lateral compartments), T2 and TCT, respectively, in both compartments while regions not covered by the meniscus experienced larger reductions of ~10%, ~2%, and ~10.5% reduction of T1ρ (p < 0.05, medial and lateral compartments), T2 and TCT (p < 0.05, lateral compartment only), respectively, in both compartments. T1ρ and T2 decreases following application of 50% body weight load were substantially larger in the tibial regions with modified Noyes grade 3 (n = 2) compared to either healthy regions (n = 85, p < 0.0.003) or regions with modified Noyes grade 2 (n = 13, p < 0.004). Interregional differences in MRI outcomes reflect variations in structure and function, and largely followed a pattern in cartilage regions that were covered or not covered by the meniscus. Results of the current study suggest that ΔT1ρ and ΔT2 values may be sensitive to superficial fissuring, more than baseline or loaded T1ρ or T2 values, or TCT alone, however future studies with additional specimens, with greater variability in OA grade distribution, may further emphasize the current findings.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Orthop Res Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: J Orthop Res Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos