Molecular epidemiology of an outbreak of Legionnaires' disease associated with a cooling tower in Genova-Sestri Ponente, Italy.
Castellani Pastoris, M; Ciceroni, L; Lo Monaco, R; Goldoni, P; Mentore, B; Flego, G; Cattani, L; Ciarrocchi, S; Pinto, A; Visca, P.
Afiliación
  • Castellani Pastoris M; Laboratorio di Batteriologia e Micologia Medica, Istituto Superiore di Sanità, Rome, Italy.
Eur J Clin Microbiol Infect Dis ; 16(12): 883-92, 1997 Dec.
Article en En | MEDLINE | ID: mdl-9495668
ABSTRACT
Fatty acid profile analysis, monoclonal antibody (MAb) subtyping, pulsed-field gel electrophoresis (PFGE), arbitrarily primed polymerase chain reaction (AP-PCR), and ribotyping were used to compare clinical and environmental Legionella pneumophila serogroup 1 isolates from an outbreak of Legionnaires' disease presumptively associated with cooling towers. According to the Oxford subtyping scheme, the MAb subtype of patients' isolates and of two strains originating from a cooling tower was Pontiac, whereas the other isolates were subtype Olda. The strains showed no intrinsic strain-to-strain difference in fatty acid profiles, and ribotyping and length polymorphism of the 16S-23S rDNA intervening regions failed to reveal any differences between the isolates. Conversely, PFGE and AP-PCR appeared to be more discriminatory, as the same genomic profile was found for the clinical and some environmental strains. Meteorologic and epidemiological data and the results of molecular analysis of the Legionella pneumophila serogroup 1 isolates support the hypothesis that the infection was transmitted from one of the cooling towers to the indoor environment of the same building, to homes in proximity that had open windows, and to the streets. In fact, the outbreak diminished and later ended after a part in the tower was replaced. This investigation demonstrates the utility of combined molecular methods (i.e., phenotypic and genomic typing) in comparing epidemiologically linked clinical and environmental isolates. Finally, the outbreak confirms the risk of Legionnaires' disease posed by cooling towers, mainly when atmospheric thermal and humidity inversions occur. This finding emphasizes the need to determine whether the source of infection is in the living or working environment or somewhere else.
Asunto(s)
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Microbiología del Agua / Enfermedad de los Legionarios / Brotes de Enfermedades / Legionella pneumophila Tipo de estudio: Observational_studies / Risk_factors_studies / Screening_studies Límite: Adult / Aged / Aged80 / Humans / Middle aged País/Región como asunto: Europa Idioma: En Revista: Eur J Clin Microbiol Infect Dis Asunto de la revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Año: 1997 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Microbiología del Agua / Enfermedad de los Legionarios / Brotes de Enfermedades / Legionella pneumophila Tipo de estudio: Observational_studies / Risk_factors_studies / Screening_studies Límite: Adult / Aged / Aged80 / Humans / Middle aged País/Región como asunto: Europa Idioma: En Revista: Eur J Clin Microbiol Infect Dis Asunto de la revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Año: 1997 Tipo del documento: Article País de afiliación: Italia