Monitoring of oxytetracycline in ovine milk by high-performance liquid chromatography.
J Pharm Biomed Anal
; 20(1-2): 321-6, 1999 Jun.
Article
em En
| MEDLINE
| ID: mdl-10704038
A method for 'in vivo' determination of the oxytetracyclin residues in ovine milk at low levels is described. Two groups of Sardinian breed sheep were treated with a dose of oxytetracycline by intramammary infusion and intramuscular administration, respectively. Oxytetracycline residues in extracts obtained from a preliminary cleanup procedure, were detected by an isocratic high-performance liquid chromatography (HPLC) method. Linear calibration plots were obtained over a large concentration range of 1 mg ml(-1)-10 ng ml(-1), with correlation coefficients higher than 0.996. Recoveries between 85.8 and 98.9% were obtained. Limit of detection (LOD) and limit of determination (LOQ) were 5.2 and 17.5 ng ml(-1), respectively. This method would be useful for routine monitoring of oxytetracycline residues in ovine dairy milk.
Buscar no Google
Bases de dados:
MEDLINE
Assunto principal:
Oxitetraciclina
/
Leite
/
Antibacterianos
Limite:
Animals
Idioma:
En
Revista:
J Pharm Biomed Anal
Ano de publicação:
1999
Tipo de documento:
Article
País de afiliação:
Itália