Your browser doesn't support javascript.
loading
Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging.
Forbes, Kirsten P; Pipe, James G; Karis, John P; Heiserman, Joseph E.
Afiliação
  • Forbes KP; Division of Neuroradiology, Barrow Neurological Institute, St Joseph's Hospital and Medical Center, 350 W Thomas Rd, Phoenix, AZ 85013, USA.
Radiology ; 225(2): 551-5, 2002 Nov.
Article em En | MEDLINE | ID: mdl-12409594
ABSTRACT

PURPOSE:

To compare periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) multishot fast spin-echo diffusion-weighted magnetic resonance (MR) imaging with single-shot echo-planar diffusion-weighted MR imaging for image quality and visualization of acute cerebral infarction. MATERIALS AND

METHODS:

Seventy subjects (35 men, 35 women; mean age, 55 years +/- 24 [SD]) who were suspected of having acute cerebral infarction (symptom duration, 2.8 days +/- 2.7) underwent PROPELLER and echo-planar MR imaging (b = 1,000 sec/mm(2)). Two neuroradiologists compared unlabeled images for presence of artifacts, visualization of infarction, and their preference of images. Interobserver agreement and image comparison were assessed by using the kappa statistic and the chi(2) test, respectively.

RESULTS:

PROPELLER MR imaging reduced susceptibility artifacts (n = 70 subjects), which limited visualization of temporal (echo-planar, n = 64; PROPELLER, n = 0; P <.01, chi(2) test), frontal (echo-planar, n = 58; PROPELLER, n = 1; P <.01), and parietal lobes (echo-planar, n = 5; PROPELLER, n = 0; P <.05) and cerebellum (echo-planar, n = 36; PROPELLER, n = 0; P <.01) and brainstem (echo-planar, n = 23; PROPELLER, n = 0; P <.01). Acute infarction (n = 31 subjects) was better demonstrated at PROPELLER MR imaging (PROPELLER better, n = 18; echo-planar better, n = 1; PROPELLER and echo-planar equal, n = 12; P <.01, chi(2) test). PROPELLER MR imaging was preferred in all (n = 70) but one case in which the lesion lay within the intersection gap (PROPELLER preferred, n = 69; echo-planar preferred, n = 1; P <.01, chi(2) test).

CONCLUSION:

With a short increase in imaging time, PROPELLER MR imaging offers better image quality and detection of acute cerebral infarction than does echo-planar MR imaging.
Assuntos
Buscar no Google
Bases de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Infarto Cerebral / Imagem Ecoplanar / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Radiology Ano de publicação: 2002 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Bases de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Infarto Cerebral / Imagem Ecoplanar / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Radiology Ano de publicação: 2002 Tipo de documento: Article País de afiliação: Estados Unidos